Your browser doesn't support javascript.
loading
Three-dimensional measurement and analysis of Mandibular Molar Distalization assisted by micro-implant anchorage combined with clear aligner.
Lin, Gengbing; Chen, Mengwei; Guo, Nan; Shi, Xie.
Afiliação
  • Lin G; Gengbing Lin, Department of Stomatology, Fujian Provincial People's Hospital, Affiliated People's Hospital of Fujian University of Traditional Chinese Medicine, Fuzhou 350004, Fujian, China.
  • Chen M; Mengwei Chen, Department of Orthodontics, Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University & Institute of Sto
  • Guo N; Nan Guo, Department of Stomatology, Fujian Provincial People's Hospital, Affiliated People's Hospital of Fujian University of Traditional Chinese Medicine, Fuzhou 350004, Fujian, China.
  • Shi X; Xie Shi, Department of Orthodontics, Fujian Key Laboratory of Oral Diseases & Fujian Provincial Engineering Research Center of Oral Biomaterial & Stomatological Key lab of Fujian College and University, School and Hospital of Stomatology, Fujian Medical University & Institute of Stomatol
Pak J Med Sci ; 40(3Part-II): 455-460, 2024.
Article em En | MEDLINE | ID: mdl-38356811
ABSTRACT

Objective:

To investigate the effect of micro-implant anchorage combined with a clear aligner on the efficiency of mandibular molar distalization and the protection of anterior teeth anchorage, provide reference for clinical scheme design.

Methods:

This is a prospective study. Seventeen patients who were treated in the Orthodontics Department of the Hospital of Stomatology affiliated to Fujian Medical University from 2019 to 2021 and used Invisalign clear aligners to move mandibular molars distally were included and divided into two groups according to anchorage types Group-A and Group-B. Group-A (ten cases) were treated without micro-implant anchorage, while Group-B (seven cases) were treated with micro-implant anchorage nails for enhanced anchorage. The effect of micro-implant anchorage on crown and root distal movement of mandibular molars and the difference in three-dimensional movement between mandibular molars and mandibular central incisors were analyzed.

Results:

The crown distalization efficiency of mandibular first and second molars in Group-B was 68.66% and 71.02%, respectively, which were higher than those in Group-A(p<0.05). The mandibular central incisors in Group-A showed labial displacement and a small amount of elongation, while those in Group-B showed less anchorage loss(p<0.05). In Group-A, the crown was tilted in the distal direction and moved in the buccal direction during mandibular molar distalization(p<0.05). While in Group-B, the crown was tilted in the distal directio (p<0.05) and the mandibular second molar was depressed(p<0.05).

Conclusion:

In the process of mandibular molar distalization assisted by micro-implant anchorage combined with a clear aligner, better protects the anchorage of the mandibular central incisor and improves the efficiency of the molar crown distalization.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article