Your browser doesn't support javascript.
loading
Fluorescent Carbon Dots: Aggregation-Induced Emission Enhancement, Application as Probe for CN- and Cr2O7-2, Sensing Strips and Bio-imaging Agent.
Bhatt, Madhuri; Bhatt, Shreya; Vyas, Gaurav; Raval, Ishan; Kumar, Anshu; Paul, Parimal.
Afiliação
  • Bhatt M; Analytical and Environmental Science Division & Centralized Instrument Facility, CSIR-Central Salt and Marine Chemicals Research Institute, G. B. Marg, Bhavnagar, 364002, India.
  • Bhatt S; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India.
  • Vyas G; Analytical and Environmental Science Division & Centralized Instrument Facility, CSIR-Central Salt and Marine Chemicals Research Institute, G. B. Marg, Bhavnagar, 364002, India.
  • Raval I; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India.
  • Kumar A; Analytical and Environmental Science Division & Centralized Instrument Facility, CSIR-Central Salt and Marine Chemicals Research Institute, G. B. Marg, Bhavnagar, 364002, India.
  • Paul P; Academy of Scientific and Innovative Research (AcSIR), Ghaziabad, 201002, India.
J Fluoresc ; 2024 Feb 17.
Article em En | MEDLINE | ID: mdl-38367156
ABSTRACT
Fluorescent carbon dots (Trp-CDs) were prepared using tryptophan as precursor and were characterized on the basis of elemental analysis, powder-XRD, IR, Raman spectroscopy, 13C-NMR, UV-Vis, fluorescence and TEM. Trp-CDs exhibit poor fluorescence in 100% water but showed strong Aggregation Induced Emission (AIE) in ethanol and higher alcohols. The anion sensing study of Trp-CD revealed that it selectively detects CN- and Cr2O7-2 and from fluorescence quenching titration study, quenching constant, LOD and range of detection were evaluated. The emission life-time of Trp-CD before and after addition of CN- and Cr2O7-2 were measured, the decay curve before addition of anion was best fitted with a bi-exponential function with life-time of τ1 2.79 ns (10.74%) and τ2 18.93 ns (89.26%). The mechanistic study revealed that for CN-, the fluorescence quenching is due to its interaction with protons attached to surface functional groups and for Cr2O7-2, it is due to inner filter effect (IFE). Sensing strips were prepared by coating Trp-CDs onto various solid surfaces including agarose films and were used for detection of CN- and Cr2O7-. Trp-CD was found to be nontoxic and biocompatible and used as staining agent for Artemia and Bacteria (Bacillus Subtilis, Pseudomonas) and detection of CN- and Cr2O7-.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article