Your browser doesn't support javascript.
loading
T790M mutation upconversion fluorescence biosensor via mild ATRP strategy and site-specific DNA cleavage of restriction endonuclease.
Liu, Yanju; Guo, Liang; Hou, Mengyuan; Gao, Haiyang; Ke, Yuanmeng; Yang, Huaixia; Si, Fuchun.
Afiliação
  • Liu Y; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, People's Republic of China.
  • Guo L; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, People's Republic of China.
  • Hou M; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, People's Republic of China.
  • Gao H; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, People's Republic of China.
  • Ke Y; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, People's Republic of China.
  • Yang H; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, People's Republic of China. yanghuaixia886@163.com.
  • Si F; Pharmacy College, Henan University of Chinese Medicine, Zhengzhou, 450046, People's Republic of China. sifc2000@hotmail.com.
Mikrochim Acta ; 191(3): 148, 2024 02 20.
Article em En | MEDLINE | ID: mdl-38374311
ABSTRACT
A unique combination of a specific nucleic acid restriction endonuclease (REase) and atom transfer radical polymerization (ATRP) signal amplification strategy was employed for the detection of T790M mutations prevalent in the adjuvant diagnosis of lung cancer. REase selectively recognizes and cleaves T790M mutation sites on double-stranded DNA formed by hybridization of a capture sequence and a target sequence. At the same time, the ATRP strategy resulted in the massive aggregation of upconverted nanoparticles (UCNPs), which significantly improved the sensitivity of the biosensor. In addition, the UCNPs have excellent optical properties and can eliminate the interference of autofluorescence in the samples, thus further improving the detection sensitivity. The proposed upconversion fluorescent biosensor is characterized by high specificity, high sensitivity, mild reaction conditions, fast response time, and a detection limit as low as 0.14 fM. The performance of the proposed biosensor is comparable to that of clinical PCR methods when applied to clinical samples. This work presents a new perspective for assisted diagnosis in the pre-intervention stage of tumor diagnostics in the early stage of precision oncology treatments.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Neoplasias Pulmonares Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Neoplasias Pulmonares Idioma: En Ano de publicação: 2024 Tipo de documento: Article