Your browser doesn't support javascript.
loading
Reliability, validity, and responsiveness of a smartphone-based manikin to support pain self-reporting.
van der Veer, Sabine N; Ali, S Mustafa; Yu, Ziqiao; McBeth, John; Chiarotto, Alessandro; James, Ben; Dixon, William G.
Afiliação
  • van der Veer SN; Centre for Health Informatics, Division of Informatics, Imaging and Data Science, Manchester Academic Health Science Centre, The University of Manchester, Manchester, United Kingdom.
  • Ali SM; Centre for Health Informatics, Division of Informatics, Imaging and Data Science, Manchester Academic Health Science Centre, The University of Manchester, Manchester, United Kingdom.
  • Yu Z; Centre for Health Informatics, Division of Informatics, Imaging and Data Science, Manchester Academic Health Science Centre, The University of Manchester, Manchester, United Kingdom.
  • McBeth J; Centre for Epidemiology Versus Arthritis, Division of Musculoskeletal and Dermatological Sciences, Manchester Academic Health Science Centre, The University of Manchester, Manchester, United Kingdom.
  • Chiarotto A; Department of General Practice, Erasmus MC, University Medical Center, Rotterdam, the Netherlands.
  • James B; uMotif, London, United Kingdom.
  • Dixon WG; Centre for Epidemiology Versus Arthritis, Division of Musculoskeletal and Dermatological Sciences, Manchester Academic Health Science Centre, The University of Manchester, Manchester, United Kingdom.
Pain Rep ; 9(2): e1131, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38375091
ABSTRACT

Introduction:

Many people worldwide suffer from chronic pain. Improving our knowledge on chronic pain prevalence and management requires methods to collect pain self-reports in large populations. Smartphone-based tools could aid data collection by allowing people to use their own device, but the measurement properties of such tools are largely unknown.

Objectives:

To assess the reliability, validity, and responsiveness of a smartphone-based manikin to support pain self-reporting.

Methods:

We recruited people with fibromyalgia, rheumatoid arthritis, and/or osteoarthritis and access to a smartphone and the internet. Data collection included the Global Pain Scale at baseline and follow-up, and 30 daily pain drawings completed on a 2-dimensional, gender-neutral manikin. After deriving participants' pain extent from their manikin drawings, we evaluated convergent and discriminative validity, test-retest reliability, and responsiveness and assessed findings against internationally agreed criteria for good measurement properties.

Results:

We recruited 131 people; 104 were included in the full sample, submitting 2185 unique pain drawings. Manikin-derived pain extent had excellent test-retest reliability (intraclass correlation coefficient, 0.94), moderate convergent validity (ρ, 0.46), and an ability to distinguish fibromyalgia and osteoarthritis from rheumatoid arthritis (F statistics, 30.41 and 14.36, respectively; P < 0.001). Responsiveness was poor (ρ, 0.2; P, 0.06) and did not meet the respective criterion for good measurement properties.

Conclusion:

Our findings suggest that smartphone-based manikins can be a reliable and valid method for pain self-reporting, but that further research is warranted to explore, enhance, and confirm the ability of such manikins to detect a change in pain over time.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article