A digital approach to fabricating a custom holder for the attachment of a mandibular sensor of an optical jaw motion tracking system: A dental technique.
Yang, Shengtao; Wang, Siyu; Zhou, Zheqing; Zhao, Dong; Yuan, Quan; Yue, Li.
Afiliação
  • Yang S; Dental Technician, State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Department of Dental Technology, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China.
  • Wang S; Undergraduate student, State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Department of Dental Technology, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China.
  • Zhou Z; Undergraduate student, State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Department of Dental Technology, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China.
  • Zhao D; Undergraduate student, State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Department of Dental Technology, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China.
  • Yuan Q; Professor and Head, Prosthodontics Department, State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Department of Oral Implantology, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China.
  • Yue L; Director, Department of Dental Technology, State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Department of Dental Technology, West China Hospital of Stomatology, Sichuan University, Chengdu, PR China. Electronic address: yuel
J Prosthet Dent ; 2024 Feb 19.
Article em En | MEDLINE | ID: mdl-38378312
ABSTRACT
A digital approach to fabricating a custom holder to attach a mandibular sensor of an optical jaw motion tracking system is described. Typically, jaw motion tracking systems come with standard holders. However, additional chairside time is still required to adapt the holder's arm to the individual arch and securely attach the holder to the mandibular teeth. Moreover, the placement of the standard holder is problematic in patients with a deep vertical overlap or with short clinical crowns. This technique offers a digital approach to designing and fabricating a custom holder in situations where standard holders cannot be efficiently attached. The custom holder is designed to accommodate the available space without interfering with the occlusion, thereby minimizing the time needed to attach the holder and optimizing the workflow for clinical jaw motion tracking.