Your browser doesn't support javascript.
loading
Smart touchless human-machine interaction based on crystalline porous cages.
Wang, Jinrong; Lin, Weibin; Chen, Zhuo; Nikolaeva, Valeriia O; Alimi, Lukman O; Khashab, Niveen M.
Afiliação
  • Wang J; Smart Hybrid Materials Laboratory (SHMs), Physical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia.
  • Lin W; Smart Hybrid Materials Laboratory (SHMs), Physical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia.
  • Chen Z; Advanced Membranes and Porous Materials Center (AMPM), King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia.
  • Nikolaeva VO; Smart Hybrid Materials Laboratory (SHMs), Physical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia.
  • Alimi LO; Smart Hybrid Materials Laboratory (SHMs), Physical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia.
  • Khashab NM; Smart Hybrid Materials Laboratory (SHMs), Physical Science and Engineering Division, King Abdullah University of Science and Technology (KAUST), Thuwal, 23955-6900, Saudi Arabia. niveen.khashab@kaust.edu.sa.
Nat Commun ; 15(1): 1575, 2024 Feb 21.
Article em En | MEDLINE | ID: mdl-38383478
ABSTRACT
The rise of touchless technology, driven by the recent pandemic, has transformed human-machine interaction (HMI). Projections indicate a substantial growth in the touchless technology market, nearly tripling from $13.6 billion in 2021 to an estimated $37.6 billion by 2026. In response to the pandemic-driven shift towards touchless technology, here we show an organic cage-based humidity sensor with remarkable humidity responsiveness, forming the basis for advanced touchless platforms in potential future HMI systems. This cage sensor boasts an ultrafast response/recovery time (1 s/3 s) and exceptional stability (over 800 cycles) across relative humidity (RH) changes from 11% to 95%. The crystal structure's 3D pore network and luxuriant water-absorbing functional groups both inside and outside of the cage contribute synergistically to superior humidity sensing. Demonstrating versatility, we showcase this cage in smart touchless control screens and touchless password managers, presenting cost-effective and easily processable applications of molecularly porous materials in touchless HMI.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article