Comparison of machine learning-based CT fractional flow reserve with cardiac MR perfusion mapping for ischemia diagnosis in stable coronary artery disease.
Eur Radiol
; 34(9): 5654-5665, 2024 Sep.
Article
em En
| MEDLINE
| ID: mdl-38409549
ABSTRACT
OBJECTIVES:
To compare the diagnostic performance of machine learning (ML)-based computed tomography-derived fractional flow reserve (CT-FFR) and cardiac magnetic resonance (MR) perfusion mapping for functional assessment of coronary stenosis.METHODS:
Between October 2020 and March 2022, consecutive participants with stable coronary artery disease (CAD) were prospectively enrolled and underwent coronary CTA, cardiac MR, and invasive fractional flow reserve (FFR) within 2 weeks. Cardiac MR perfusion analysis was quantified by stress myocardial blood flow (MBF) and myocardial perfusion reserve (MPR). Hemodynamically significant stenosis was defined as FFR ≤ 0.8 or > 90% stenosis on invasive coronary angiography (ICA). The diagnostic performance of CT-FFR, MBF, and MPR was compared, using invasive FFR as a reference.RESULTS:
The study protocol was completed in 110 participants (mean age, 62 years ± 8; 73 men), and hemodynamically significant stenosis was detected in 36 (33%). Among the quantitative perfusion indices, MPR had the largest area under receiver operating characteristic curve (AUC) (0.90) for identifying hemodynamically significant stenosis, which is in comparison with ML-based CT-FFR on the vessel level (AUC 0.89, p = 0.71), with comparable sensitivity (89% vs 79%, p = 0.20), specificity (87% vs 84%, p = 0.48), and accuracy (88% vs 83%, p = 0.24). However, MPR outperformed ML-based CT-FFR on the patient level (AUC 0.96 vs 0.86, p = 0.03), with improved specificity (95% vs 82%, p = 0.01) and accuracy (95% vs 81%, p < 0.01).CONCLUSION:
ML-based CT-FFR and quantitative cardiac MR showed comparable diagnostic performance in detecting vessel-specific hemodynamically significant stenosis, whereas quantitative perfusion mapping had a favorable performance in per-patient analysis. CLINICAL RELEVANCE STATEMENT ML-based CT-FFR and MPR derived from cardiac MR performed well in diagnosing vessel-specific hemodynamically significant stenosis, both of which showed no statistical discrepancy with each other. KEY POINTS ⢠Both machine learning (ML)-based computed tomography-derived fractional flow reserve (CT-FFR) and quantitative perfusion cardiac MR performed well in the detection of hemodynamically significant stenosis. ⢠Compared with stress myocardial blood flow (MBF) from quantitative perfusion cardiac MR, myocardial perfusion reserve (MPR) provided higher diagnostic performance for detecting hemodynamically significant coronary artery stenosis. ⢠ML-based CT-FFR and MPR from quantitative cardiac MR perfusion yielded similar diagnostic performance in assessing vessel-specific hemodynamically significant stenosis, whereas MPR had a favorable performance in per-patient analysis.Palavras-chave