Your browser doesn't support javascript.
loading
A real-time patient-specific treatment strategy for enhanced external counterpulsation.
Li, Bao; Liu, Youjun; Li, Guangfei; Zhang, Zhe; Feng, Yue; Mao, Boyan.
Afiliação
  • Li B; Department of Biomedical Engineering, College of Chemistry and Life Science, Beijing University of Technology, Beijing, China.
  • Liu Y; Department of Biomedical Engineering, College of Chemistry and Life Science, Beijing University of Technology, Beijing, China.
  • Li G; Department of Biomedical Engineering, College of Chemistry and Life Science, Beijing University of Technology, Beijing, China.
  • Zhang Z; Department of Cardiac Surgery, Peking University Third Hospital, Beijing, China.
  • Feng Y; Medical Equipment Department, Peking University First Hospital, Beijing, China.
  • Mao B; Department of Biological Engineering, School of Life Sciences, Beijing University of Chinese Medicine, Beijing, China.
Int J Numer Method Biomed Eng ; 40(4): e3808, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38409940
ABSTRACT
Diastolic/systolic blood pressure ratio (D/S) ≥ 1.2 is the gold standard of enhanced external counterpulsation (EECP) treatment, but it does not show a clear clinical correspondence with the configuration of the EECP mode. As such, a single target results in different treatment effects in different individuals. The local haemodynamic effect (wall shear stress, WSS) of EECP on vascular endothelial cells is conducive to promote the growth of collateral circulation vessels and restore the blood supply distal to the stenosis lesion. Considering the haemodynamic effects of WSS on human arteries, this study developed a real-time patient-specific treatment strategy of EECP for patients with cardio-cerebrovascular diseases. Based on patient-specific haemodynamic data from 113 individuals, an optimization algorithm was developed to achieve the individualization of a 0D lumped-parameter model of the human circulatory system, thereby simulating the patient-specific global haemodynamic effects. 0D/3D coupled cardio-cerebrovascular models of two subjects were established to simulate the local WSS. We then established statistical models to evaluate clinically unmeasurable WSS based on measurable global haemodynamic indicators. With the aim of attaining appropriate area- and time-averaged WSS (ATAWSS, 4-7 Pa), as evaluated by global haemodynamic indicators, a closed-loop feedback tuning method was developed to provide patient-specific EECP treatment strategies. Results showed that for clinical data collected from 113 individuals, the individualized 0D model can accurately simulate patient-specific global haemodynamic effects (average error <5%). Based on two subjects, the statistical models can be used to evaluate local ATAWSS (error <6%) for coronary arteries and for cerebral arteries. An EECP mode planned by the patient-specific treatment strategy can promote an appropriate ATAWSS within a 16 s calculation time. The real-time patient-specific treatment strategy of EECP is expected to improve the long-term outcome for each patient and have potential clinical significance.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Contrapulsação / Células Endoteliais Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Contrapulsação / Células Endoteliais Idioma: En Ano de publicação: 2024 Tipo de documento: Article