Capacitive Pressure Sensor Combining Dual Dielectric Layers with Integrated Composite Electrode for Wearable Healthcare Monitoring.
Li, Xinyue; Liu, Yannan; Ding, Yarong; Zhang, Miao; Lin, Zhenhua; Hao, Yue; Li, Yingchun; Chang, Jingjing.
Afiliação
  • Li X; Advanced Interdisciplinary Research Center for Flexible Electronics, Academy of Advanced Interdisciplinary Research, Xidian University, Xi'an 710071, China.
  • Liu Y; State Key Discipline Laboratory of Wide Band Gap Semiconductor Technology, School of Microelectronics, Xidian University, Xi'an 710071, China.
  • Ding Y; Shaanxi Key Laboratory of Degradable Biomedical Materials, School of Chemical Engineering, Northwest University, Xi'an 710069, China.
  • Zhang M; State Key Discipline Laboratory of Wide Band Gap Semiconductor Technology, School of Microelectronics, Xidian University, Xi'an 710071, China.
  • Lin Z; Advanced Interdisciplinary Research Center for Flexible Electronics, Academy of Advanced Interdisciplinary Research, Xidian University, Xi'an 710071, China.
  • Hao Y; State Key Discipline Laboratory of Wide Band Gap Semiconductor Technology, School of Microelectronics, Xidian University, Xi'an 710071, China.
  • Li Y; State Key Discipline Laboratory of Wide Band Gap Semiconductor Technology, School of Microelectronics, Xidian University, Xi'an 710071, China.
  • Chang J; Advanced Interdisciplinary Research Center for Flexible Electronics, Academy of Advanced Interdisciplinary Research, Xidian University, Xi'an 710071, China.
ACS Appl Mater Interfaces ; 16(10): 12974-12985, 2024 Mar 13.
Article em En | MEDLINE | ID: mdl-38416692
ABSTRACT
Foot activity can reflect numerous physiological abnormalities in the human body, making gait a valuable metric in health monitoring. Research on flexible sensors for gait monitoring has focused on high sensitivity, wide working range, fast response, and low detection limit, but challenges remain in areas such as elasticity, antibacterial activity, user-friendliness, and long-term stability. In this study, we have developed a novel capacitive pressure sensor that offers an ultralow detection limit of 1 Pa, wide detection ranges from 1 Pa to 2 MPa, a high sensitivity of 0.091 kPa-1, a fast response time of 71 ms, and exceptional stability over 6000 cycles. This sensor not only has the ability of accurately discriminating mechanical stimuli but also meets the requirements of elasticity, antibacterial activity, wearable comfort, and long-term stability for gait monitoring. The fabrication method of a dual dielectric layer and integrated composite electrode is simple, cost-effective, stable, and amenable to mass production. Thereinto, the introduction of a dual dielectric layer, based on an optimized electrospinning network and micropillar array, has significantly improved the sensitivity, detection range, elasticity, and antibacterial performance of the sensor. The integrated flexible electrodes are made by template method using composite materials of carbon nanotubes (CNTs), two-dimensional titanium carbide Ti3C2Tx (MXene), and polydimethylsiloxane (PDMS), offering synergistic advantages in terms of conductivity, stability, sensitivity, and practicality. Additionally, we designed a smart insole that integrates the as-prepared sensors with a miniature instrument as a wearable platform for gait monitoring and disease warning. The developed sensor and wearable platform offer a cutting-edge solution for monitoring human activity and detecting diseases in a noninvasive manner, paving the way for future wearable devices and personalized healthcare technologies.