Your browser doesn't support javascript.
loading
A simple and accurate ratiometric sensor for determination of dopamine based on dual-emission carbon dots.
Zhang, Yuecheng; Sun, Lingbo; Li, Chengjia; Ma, Jing; Zhang, Shiyu; Wang, QingQing; Ma, Hongyan.
Afiliação
  • Zhang Y; College of Chemistry and Chemical Engineering, Key Laboratory of Analytical Technology and Detection of Yan'an, Yan'an University, Yan'an, 716000, Shaanxi, People's Republic of China.
  • Sun L; Medical College of Yan'an University, Yan'an University, Yan'an, 716000, Shaanxi, People's Republic of China. lingbosun@yau.edu.cn.
  • Li C; College of Chemistry and Chemical Engineering, Key Laboratory of Analytical Technology and Detection of Yan'an, Yan'an University, Yan'an, 716000, Shaanxi, People's Republic of China.
  • Ma J; College of Chemistry and Chemical Engineering, Key Laboratory of Analytical Technology and Detection of Yan'an, Yan'an University, Yan'an, 716000, Shaanxi, People's Republic of China.
  • Zhang S; College of Chemistry and Chemical Engineering, Key Laboratory of Analytical Technology and Detection of Yan'an, Yan'an University, Yan'an, 716000, Shaanxi, People's Republic of China.
  • Wang Q; College of Chemistry and Chemical Engineering, Key Laboratory of Analytical Technology and Detection of Yan'an, Yan'an University, Yan'an, 716000, Shaanxi, People's Republic of China.
  • Ma H; College of Chemistry and Chemical Engineering, Key Laboratory of Analytical Technology and Detection of Yan'an, Yan'an University, Yan'an, 716000, Shaanxi, People's Republic of China. mahy6614@yau.edu.cn.
Anal Sci ; 40(6): 1023-1030, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38430366
ABSTRACT
Dopamine (DA) is a neuromodulatory molecule that plays critical roles in many biological processes. The dysfunctions of the DA system are closely associated with several nervous system diseases. Therefore, it is urgent to establish a simple and accurate method for DA analysis. In this study, an economic and accurate DA ratiometric sensor was established using dual-emission carbon dots (DE-CDs). DE-CDs were first synthesized by the one-step solvothermal method and two separate fluorescence emission peaks at 340 and 500 nm were observed under the excitation of 310 nm. In the presence of Hg2+, the fluorescence signal at 340 nm was significantly quenched, while the signal at 500 nm keeps stable. Upon adding DA, the quenched signal at 340 nm was significantly recovered, whereas the signal at 500 nm remains stable. Therefore, a novel ratiometric sensor for DA analysis was established. This method shows a good linear range from 500 nM to 100 µM, and the detection limit was calculated to be 80 nM. Moreover, this established method shows excellent specificity and could be applied in real sample analysis, showing great potential for application in clinical research.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Fluorescência Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Fluorescência Idioma: En Ano de publicação: 2024 Tipo de documento: Article