Your browser doesn't support javascript.
loading
Comparing urine point-of-care tests to screen preeclampsia: Congo-red dot paper test versus dipstick urinalysis.
Wang, Liying; Gao, Jinsong; Tang, Pingping; Hu, Huiying; Chen, Xiaoxu; Chen, Ziyi; Sun, Yin.
Afiliação
  • Wang L; Department of Obstetrics and Gynecology, Chinese Academy of Medical Sciences, Peking Union Medical College, National Clinical Research Center for Obstetric and Gynecologic Diseases, Peking Union Medical College Hospital, Beijing, China.
  • Gao J; Department of Obstetrics and Gynecology, Chinese Academy of Medical Sciences, Peking Union Medical College, National Clinical Research Center for Obstetric and Gynecologic Diseases, Peking Union Medical College Hospital, Beijing, China.
  • Tang P; Department of Obstetrics and Gynecology, Chinese Academy of Medical Sciences, Peking Union Medical College, National Clinical Research Center for Obstetric and Gynecologic Diseases, Peking Union Medical College Hospital, Beijing, China.
  • Hu H; Department of Obstetrics and Gynecology, Chinese Academy of Medical Sciences, Peking Union Medical College, National Clinical Research Center for Obstetric and Gynecologic Diseases, Peking Union Medical College Hospital, Beijing, China.
  • Chen X; Department of Obstetrics and Gynecology, Chinese Academy of Medical Sciences, Peking Union Medical College, National Clinical Research Center for Obstetric and Gynecologic Diseases, Peking Union Medical College Hospital, Beijing, China.
  • Chen Z; Department of Obstetrics and Gynecology, Chinese Academy of Medical Sciences, Peking Union Medical College, National Clinical Research Center for Obstetric and Gynecologic Diseases, Peking Union Medical College Hospital, Beijing, China.
  • Sun Y; Department of Obstetrics and Gynecology, Chinese Academy of Medical Sciences, Peking Union Medical College, National Clinical Research Center for Obstetric and Gynecologic Diseases, Peking Union Medical College Hospital, Beijing, China.
J Clin Hypertens (Greenwich) ; 26(4): 349-354, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38430477
ABSTRACT
To compare the urine Congo-red dot paper test (CRD) with dipstick urinalysis to screen preeclampsia (PE). A total of 409 paired spot urine samples were obtained prospectively from women with suspected pre-eclampsia attending for routine hospital visits. Congo-red dot paper test and dipstick urinalysis were examined and compared to screen pre-eclampsia. The agreement between the two urinary test is modest (kappa coefficient = 0.28, 95% CI 0.14-0.42). The specificity of CRD was higher than urinalysis (97.4% vs. 90.4%, p < .001). Urinalysis performed better in sensitivity (77.3% vs. 40.9%, p = .04) and the area under the receiver operating characteristic curves (AUC) (0.84 [95% CI 0.74-0.94] vs. 0.69 [95% CI 0.55-0.83], p = .04) than CRD, respectively. The sensitivity, specificity, AUC of the parallel test of them is 86.4% (64.0%-96.4%), 89.1% (85.5%-92.0%), and 0.88 (95% CI 0.79-0.96). And the serial test is 31.8% (14.7%-54.9%), 98.7% (96.8%-99.5%), 0.65 (95% CI 0.51-0.79), accordingly. The urinalysis is a better diagnosing test for preeclampsia. CRD could aid in the diagnosis of patients with preeclampsia. Combined the two tests in suspected patients may further improve the performance in the diagnosis of preeclampsia. Further study need to be made for its potential clinical practice.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pré-Eclâmpsia / Hipertensão Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Pré-Eclâmpsia / Hipertensão Idioma: En Ano de publicação: 2024 Tipo de documento: Article