Elevated middle cerebral artery peak systolic velocity and risk of death in donor twin affected by twin-twin transfusion syndrome but not twin anemia-polycythemia sequence.
Ultrasound Obstet Gynecol
; 64(2): 222-227, 2024 Aug.
Article
em En
| MEDLINE
| ID: mdl-38437460
ABSTRACT
OBJECTIVES:
To determine the association between elevated (> 1.5 multiples of the median (MoM)) middle cerebral artery (MCA) peak systolic velocity (PSV) and fetal demise of the donor twin in pregnancies complicated by twin-twin transfusion syndrome (TTTS) in the absence of twin anemia-polycythemia sequence (TAPS). Secondary objectives were to evaluate if donor or recipient MCA-PSV is associated with a risk for their corresponding fetal death, and to compare the proportion of donor fetuses with low MCA pulsatility index (PI) among donor twins with high MCA-PSV and those with normal MCA-PSV to evaluate the contribution of blood-flow redistribution to the fetal brain in donor twins with high MCA-PSV.METHODS:
This prospective cohort study included TTTS cases that underwent laser surgery between 2011 and 2022 at a single center. TAPS cases were excluded from the study. Multivariable and Poisson regression analysis were performed to explore the association between isolated elevated donor MCA-PSV and fetal demise, adjusted for TTTS stage, selective fetal growth restriction (sFGR) and other confounders.RESULTS:
Of 660 TTTS cases, donor MCA-PSV was not recorded in 48 (7.3%) cases. Of the remaining 612 patients, nine (1.5%) were lost to follow-up and 96 TAPS cases were excluded; thus, 507 cases were included in the study. High donor MCA-PSV was seen in 6.5% (33/507) of cases and was an independent risk factor for donor fetal demise (adjusted relative risk (aRR), 4.52 (95% CI, 2.72-7.50)), after adjusting for confounders. Regression analysis restricted to each Quintero TTTS stage demonstrated that high donor MCA-PSV was an independent risk factor for fetal demise of the donor in Quintero Stage II (aRR, 14.21 (95% CI, 1.09-186.2)) and Quintero Stage III (aRR, 3.41 (95% CI, 1.82-6.41)). Donor MCA-PSV in MoM was associated with fetal demise of the donor (area under the receiver-operating-characteristics curve (AUC), 0.69; P < 0.001), but recipient MCA-PSV in MoM was not associated with fetal demise of the recipient (AUC, 0.54; P = 0.44). A higher proportion of donor twins in the group with high MCA-PSV had a low MCA-PI compared to the group with normal MCA-PSV (33.3% vs 15.5%; P = 0.016).CONCLUSIONS:
Elevated donor MCA-PSV without TAPS prior to laser surgery for TTTS is associated with a 4-fold increased risk for donor fetal demise, adjusted for sFGR, TTTS stage and other confounders. Doppler evaluation of donor MCA-PSV prior to laser surgery may help stratify TTTS staging to evaluate the risk of donor fetal demise. © 2024 International Society of Ultrasound in Obstetrics and Gynecology.Palavras-chave
Texto completo:
1
Base de dados:
MEDLINE
Assunto principal:
Policitemia
/
Ultrassonografia Pré-Natal
/
Artéria Cerebral Média
/
Morte Fetal
/
Transfusão Feto-Fetal
Idioma:
En
Ano de publicação:
2024
Tipo de documento:
Article