Your browser doesn't support javascript.
loading
Synthesis of carbon nanotubes-chitosan nanocomposite and immunosensor fabrication for myoglobin detection: An acute myocardial infarction biomarker.
Rabbani, Gulam; Ahmad, Ejaz; Khan, Mohammad Ehtisham; Khan, Anwar Ulla; Zamzami, Mazin A; Ahmad, Abrar; Ali, Syed Kashif; Bashiri, Abdullateef H; Zakri, Waleed.
Afiliação
  • Rabbani G; IT-medical Fusion Center, 350-27 Gumidae-ro, Gumi-si, Gyeongbuk 39253, Republic of Korea. Electronic address: rbbgulam@gmail.com.
  • Ahmad E; Department of Pathology, University of Michigan Medical School, Ann Arbor, MI 48109, United States of America.
  • Khan ME; Department of Chemical Engineering Technology, College of Applied Industrial Technology, Jazan University, Jazan 45142, Saudi Arabia. Electronic address: mekhan@jazanu.edu.sa.
  • Khan AU; Department of Electrical Engineering Technology, College of Applied Industrial Technology, Jazan University, Jazan 45142, Saudi Arabia.
  • Zamzami MA; Department of Biochemistry, Faculty of Science, King Abdulaziz University, Jeddah 21452, Saudi Arabia.
  • Ahmad A; Department of Biochemistry, Faculty of Science, King Abdulaziz University, Jeddah 21452, Saudi Arabia.
  • Ali SK; Department of Physical Sciences, Chemistry Division, College of Science, Jazan University, P.O. Box. 114, Jazan 45142, Kingdom of Saudi Arabia; Nanotechnology research unit, College of Science, Jazan University, P.O. Box. 114, Jazan 45142, Kingdom of Saudi Arabia.
  • Bashiri AH; Department of Mechanical Engineering, College of Engineering, Jazan University, P. O. Box 114, Jazan 45142, Saudi Arabia.
  • Zakri W; Department of Mechanical Engineering, College of Engineering, Jazan University, P. O. Box 114, Jazan 45142, Saudi Arabia.
Int J Biol Macromol ; 265(Pt 1): 130616, 2024 Apr.
Article em En | MEDLINE | ID: mdl-38447842
ABSTRACT
The use of single-walled carbon nanotubes (SWCNTs) in biomedical applications is limited due to their inability to disperse in aqueous solutions. In this study, dispersed -COOH functionalized CNTs with N-succinylated chitosan (CS), greatly increasing the water solubility of CNTs and forming a uniformly dispersed nanocomposite solution of CNTs@CS. Coupling reagent EDC/NHS was used as a linker with the -COOH groups present on the N-succinylated chitosan which significantly improved the affinity of the CNTs for biomolecules. Myoglobin (Mb) is a promising biomarker for the precise assessment of cardiovascular risk, type 2 diabetes, metabolic syndrome, hypertension and several types of cancer. A high level of Mb can be used to diagnose the mentioned pathogenic diseases. The CNTs@CS-FET demonstrates superior sensing performance for Mb antigen fortified in buffer, with a wide linear range of 1 to 4000 ng/mL. The detection limit of the developed Mb immunosensor was estimated to be 4.2 ng/mL. The novel CNTs@CS-FET immunosensor demonstrates remarkable capability in detecting Mb without being affected by interferences from nonspecific antigens. Mb spiked serum showed a recovery rate of 100.262 to 118.55 % indicating great promise for Mb detection in clinical samples. The experimental results confirmed that the CNTs@CS-FET immunosensor had excellent selectivity, reproducibility and storage stability.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanotubos de Carbono / Quitosana / Diabetes Mellitus Tipo 2 / Nanocompostos / Infarto do Miocárdio Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Nanotubos de Carbono / Quitosana / Diabetes Mellitus Tipo 2 / Nanocompostos / Infarto do Miocárdio Idioma: En Ano de publicação: 2024 Tipo de documento: Article