ABSTRACT

OBJECTIVE:

In an effort to avoid postoperative sick sinus syndrome( SSS), we omit the ablation line to the superior vena cava( SVC) in the Cox-mazeⅢ lesion set. We report the long-term outcomes, including the freedom from SSS.

METHODS:

We studied 102 patients who underwent bi-atrial maze procedure for persistent atrial fibrillation (Af) from 2009 through 2023. Bipolar radio frequency ablation or cryoablation was used except for right-side atriotomy and right atriotomy. Cryoablation was used for atrioventricular annulus. The patient age was 68±9.4. Duration of Af was 3.4±6.5 years (unknown 9 cases). The amplitude of f-wave in V1 was 0.182±0.095 mV and it was<0.1 mV in 19 (18.6%). Diameter of the left atrium was 50±8.9 mm, and left atrial volume index was 89±37 ml/m2. Ninety-one (89.2%) patients underwent concomitant mitral valve surgery.

RESULTS:

Survival rate was 99% at 1 year and 96% at 5 years. Freedom from Af was 92% at 1 year and 88% at 5 years. Freedom from permanent pacemaker implantation (PPI) was 87% at 1 year and 83% at 5 years.

CONCLUSIONS:

Defibrillation rate and the incidence of PPI was comparable to those in previous reports after standard Cox-mazeⅢ. SSS after maze for persistent Af seem due to patient.