Your browser doesn't support javascript.
loading
Quantitative analysis of abdominal aortic blood flow by 99mTc-DTPA renal scintigraphy in patients with heart failure.
Li, Yue; Yang, Zhiqiang; Yin, Pei; Gao, Xian; Li, Lizhuo; Zhao, Qingzhen; Zhen, Yuzhi; Wang, Yu; Liu, Chao.
Afiliação
  • Li Y; Heart Failure Center, The First Hospital of Hebei Medical University, Hebei Medical University, 89 Donggang Road, Shijiazhuang, 050031, Hebei, China.
  • Yang Z; Department of Cardiology, The Second Hospital of Hebei Medical University, 215 Heping Road, Shijiazhuang, 050000, Hebei, China.
  • Yin P; Cardiovascular Research Center of Hebei Medical University, Shijiazhuang, 050000, Hebei, China.
  • Gao X; Heart Failure Center, The First Hospital of Hebei Medical University, Hebei Medical University, 89 Donggang Road, Shijiazhuang, 050031, Hebei, China.
  • Li L; Division of Nuclear Medicine, The First Hospital of Hebei Medical University, Shijiazhuang, 050031, Hebei, China.
  • Zhao Q; Health Institute of The First Hospital of Hebei Medical University, Shijiazhuang, 050031, Hebei, China.
  • Zhen Y; Heart Failure Center, The First Hospital of Hebei Medical University, Hebei Medical University, 89 Donggang Road, Shijiazhuang, 050031, Hebei, China.
  • Wang Y; Heart Failure Center, The First Hospital of Hebei Medical University, Hebei Medical University, 89 Donggang Road, Shijiazhuang, 050031, Hebei, China.
  • Liu C; Heart Failure Center, The First Hospital of Hebei Medical University, Hebei Medical University, 89 Donggang Road, Shijiazhuang, 050031, Hebei, China.
Ann Nucl Med ; 38(6): 418-427, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38466548
ABSTRACT

OBJECTIVE:

This study aimed to explore the characteristics of abdominal aortic blood flow in patients with heart failure (HF) using 99mTc-diethylenetriaminepentaacetic acid (DTPA) renal scintigraphy. We investigated the ability of renal scintigraphy to measure the cardiopulmonary transit time and assessed whether the time-to-peak of the abdominal aorta (TTPa) can distinguish between individuals with and without HF.

METHODS:

We conducted a retrospective study that included 304 and 37 patients with and without HF (controls), respectively. All participants underwent 99mTc-DTPA renal scintigraphy. The time to peak from the abdominal aorta's first-pass time-activity curve was noted and compared between the groups. The diagnostic significance of TTPa for HF was ascertained through receiver operating characteristic (ROC) analysis and logistic regression. Factors influencing the TTPa were assessed using ordered logistic regression.

RESULTS:

The HF group displayed a significantly prolonged TTPa than controls (18.5 [14, 27] s vs. 11 [11, 13] s). Among the HF categories, HF with reduced ejection fraction (HFrEF) exhibited the longest TTPa compared with HF with mildly reduced (HFmrEF) and preserved EF (HFpEF) (25 [17, 36.5] s vs. 17 [15, 23] s vs. 15 [11, 17] s) (P < 0.001). The ROC analysis had an area under the curve of 0.831, which underscored TTPa's independent diagnostic relevance for HF. The diagnostic precision was enhanced as left ventricular ejection fraction (LVEF) declined and HF worsened. Independent factors for TTPa included the left atrium diameter, LVEF, right atrium diameter, velocity of tricuspid regurgitation, and moderate to severe aortic regurgitation.

CONCLUSIONS:

Based on 99mTc-DTPA renal scintigraphy, TTPa may be used as a straightforward and non-invasive tool that can effectively distinguish patients with and without HF.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aorta Abdominal / Pentetato de Tecnécio Tc 99m / Insuficiência Cardíaca / Rim Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Aorta Abdominal / Pentetato de Tecnécio Tc 99m / Insuficiência Cardíaca / Rim Idioma: En Ano de publicação: 2024 Tipo de documento: Article