Anterior Segment Biometry During Accommodation After Posterior Chamber Phakic Implantable Collamer Lens Implantation.
J Refract Surg ; 40(3): e164-e172, 2024 Mar.
Article em En | MEDLINE | ID: mdl-38466765
ABSTRACT

PURPOSE:

To evaluate the dynamic changes in anterior segment parameters during accommodation following Implantable Collamer Lens (ICL) implantation with swept-source optical coherence tomography (SS-OCT).

METHODS:

Under the accommodation of 0.00 diopters (D), 3.00 D, and maximum amplitude, SS-OCT was used to examine the anterior segment parameters, including ICL vault, ICL depth (the distance between the corneal endothelium and the posterior surface of ICL), crystalline lens thickness, anterior chamber depth, and various parameters of the anterior chamber angle, comprising angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle.

RESULTS:

During accommodation, the ICL vault showed a significant decrease from baseline (536 ± 278 µm) to 3.00 D (522 ± 281 µm), followed by an increase from 3.00 D to maximum amplitude (548 ± 306 µm) (analysis of variance [ANOVA], P < .001). Four eyes (2.61%) exhibited a decrease in ICL vault to less than 100 µm (47 ± 32 µm) at maximum accommodation. The ICL depth decreased significantly as accommodation increased (ANOVA, P < .001). Crystalline lens thickness increased, whereas anterior chamber depth decreased during accommodation (ANOVA, P < .001). The anterior chamber angle widened during 3.00 D of accommodation but narrowed at maximum accommodation, leading to significant changes in the angle opening distance, angle recess area, trabecular iris space area, and trabecular iris angle during accommodation (ANOVA, P < .001 for all).

CONCLUSIONS:

The anterior segment, including ICL vault and anterior chamber angle, undergo significant dynamic changes during accommodation. These accommodative changes may require careful monitoring for the surgery design of ICL implantation. [J Refract Surg. 2024;40(3)e164-e172.].