Design and Implementation of a Specialised Millimetre-Wave Exposure System for Investigating the Radiation Effects of 5G and Future Technologies.
Foroughimehr, Negin; Wood, Andrew; McKenzie, Ray; Karipidis, Ken; Yavari, Ali.
Afiliação
  • Foroughimehr N; 6G Research and Innovation Lab, Swinburne University of Technology, Melbourne, VIC 3122, Australia.
  • Wood A; School of Science, Computing and Engineering Technologies, Swinburne University of Technology, Melbourne, VIC 3122, Australia.
  • McKenzie R; School of Health Sciences, Swinburne University of Technology, Melbourne, VIC 3122, Australia.
  • Karipidis K; 6G Research and Innovation Lab, Swinburne University of Technology, Melbourne, VIC 3122, Australia.
  • Yavari A; School of Health Sciences, Swinburne University of Technology, Melbourne, VIC 3122, Australia.
Sensors (Basel) ; 24(5)2024 Feb 26.
Article em En | MEDLINE | ID: mdl-38475053
ABSTRACT
As the fifth-generation (5G) network is introduced in the millimetre-wave (mmWave) spectrum, and the widespread deployment of 5G standalone (SA) is approaching, it becomes essential to establish scientifically grounded exposure limits in the mmWave frequency band. To achieve this, conducting experiments at specific frequencies is crucial for obtaining reliable evidence of potential biological impacts. However, there is a literature gap where experimental research either does not utilise the mmWave high band (e.g., the 26 Gigahertz (GHz) band) or most studies mainly rely on computational approaches. Moreover, some experimental studies do not establish reproducible test environment and exposure systems. Addressing these gaps is vital for a comprehensive exploration of the biological implications associated with mmWave exposure. This study was designed to develop and implement a mmWave exposure system operating at 26 GHz. The step-by-step design and development of the system are explained. This specialised system was designed and implemented within an anechoic chamber to minimise external electromagnetic (EM) interference, creating a controlled and reproducible environment for experiments involving high-frequency EM fields. The exposure system features a 1 cm radiation spot size, enabling highly localised exposure for various biological studies. This configuration facilitates numerous dosimetry studies related to mmWave frequencies.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article