Your browser doesn't support javascript.
loading
Bactericidal efficacy of lithium magnesium silicate hydrosol incorporated with slightly acidic electrolyzed water in disinfection application against Escherichia coli.
Aleryani, Hamzah; Qing, Gao; Sri Prabakusuma, Adhita; Abdo, Abdullah; Al-Dalali, Sam; Al-Zamani, Zakarya; Xintan, Jian; Jin-Song, He.
Afiliação
  • Qing G; College of Food Science and Technology, Yunnan Agricultural University, Kunming, China.
  • Sri Prabakusuma A; College of Food Science and Technology, Yunnan Agricultural University, Kunming, China.
  • Abdo A; Food Biotechnology Research Group, Vocational School of Foodservice Industry, Universitas Ahmad Dahlan, Yogyakarta, Indonesia.
  • Al-Dalali S; College of Food Science and Technology, Hebei Agricultural University, Baoding, China.
  • Al-Zamani Z; Department of Food Sciences, Faculty of Agriculture and Food Sciences, Ibb University, Yemen.
  • Xintan J; Department of Food Sciences, Faculty of Agriculture and Food Sciences, Ibb University, Yemen.
  • Jin-Song H; Department of Food Sciences, Faculty of Agriculture and Food Sciences, Ibb University, Yemen.
Ital J Food Saf ; 13(1): 11587, 2024 Feb 22.
Article em En | MEDLINE | ID: mdl-38481767
ABSTRACT
In food safety implementation, bacterial inactivation is an imperative aspect of hygiene and sanitation. Studies on lithium magnesium silicate (LMS) hydrosol incorporated with slightly acidic electrolyzed water (SAEW) for decontamination of pathogenic bacteria are limited. This present study aimed to investigate the bactericidal efficacy of LMS hydrosol incorporated with SAEW against Escherichia coli. Optimum combination conditions of SAEW, hydrosol concentration, and available chlorine concentration (ACC) were optimized by response surface methodology under the central composite design against the growth of E. coli. The optimum combination conditions of exposure time, hydrosol concentration, and ACC were 9.5 minutes, 1.7%, and 20.5 ppm, respectively. The results showed that the increase in ACC led to inactivation in the survival of E. coli compared with the control (p<0.05). It can be concluded that the best combination percentage between SAEW and hydrosol ranged from 1.5-1.7%, in which E. coli was reduced by 4.50 log10 CFU/mL at an ACC of 9.94 ppm. When increasing the ACC to 14.84 ppm, E. coli was reduced by 4.51 log10 CFU/mL compared with the initial number of bacteria (8.20 log10 CFU/mL) in the control group. The number of bacteria was undetected after increasing ACC to 19.93, 25.15, and 29.88 ppm at 10 min. This study suggests that LMS hydrosol incorporated with SAEW could potentially be used as an effective sanitizer.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article