Suture Bridge Technique with 5-Ethibond: A Promising Approach for Infrapatellar Pole Fracture Treatment.
Hu, Jinlong; Zhang, Jiale; Zhang, Pei; Wang, Jingcheng; He, Jinshan; Chen, Pengtao; Liang, Yuan.
Afiliação
  • Hu J; Department of Orthopedics Clinical Medical College, Yangzhou University, Northern Jiangsu People's Hospital, Nantong West Road 98, Yangzhou, 225001, China.
  • Zhang J; Department of Orthopedics Clinical Medical College, Yangzhou University, Northern Jiangsu People's Hospital, Nantong West Road 98, Yangzhou, 225001, China.
  • Zhang P; Department of Orthopedics Clinical Medical College, Yangzhou University, Northern Jiangsu People's Hospital, Nantong West Road 98, Yangzhou, 225001, China.
  • Wang J; Department of Orthopedics Clinical Medical College, Yangzhou University, Northern Jiangsu People's Hospital, Nantong West Road 98, Yangzhou, 225001, China.
  • He J; Department of Orthopedics Clinical Medical College, Yangzhou University, Northern Jiangsu People's Hospital, Nantong West Road 98, Yangzhou, 225001, China.
  • Chen P; Department of Orthopedics Clinical Medical College, Yangzhou University, Northern Jiangsu People's Hospital, Nantong West Road 98, Yangzhou, 225001, China.
  • Liang Y; Department of Orthopedics Clinical Medical College, Yangzhou University, Northern Jiangsu People's Hospital, Nantong West Road 98, Yangzhou, 225001, China.
Orthop Rev (Pavia) ; 16: 94275, 2024.
Article em En | MEDLINE | ID: mdl-38505135
ABSTRACT

Purpose:

Infrapatellar pole fractures are challenging injuries that require appropriate treatment to ensure optimal functional outcomes. This study aimed to introduce the application of the Suture Bridge technique using the 5-Ethibond for the treatment of infrapatellar patella fracture.

Methods:

Five cases of infrapatellar pole fracture that were treated at our institution between February 2020 and September 2021. The patients included one male and four females, with an average age of 66 years (range 60-77 years). All patients were treated with the Suture Bridge technique using the 5-Ethibond to preserve the infrapatellar pole.

Results:

The average operative time was 64 min (range 50-80 min). The average blood loss during surgery was 51 mL (range 40-60 mL). All cases demonstrated fracture healing at an average of 10 weeks (range 8-12) after surgery. The patients were followed up for an average period of 14.8 months (8-22). No wound infection or second displacement of fracture fragment was found. Full range of motion was restored in all patients within 12-14 weeks after surgery. None of the patients complained of anterior knee pain.

Conclusions:

Based on the findings of the study, it appears that the Suture Bridge technique using 5-Ethibond is a promising and viable option for the treatment of infrapatellar pole fractures.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article