Your browser doesn't support javascript.
loading
Design and evaluation of loop-mediated isothermal amplification for rapid detection of Enterocytozoon bieneusi.
Mahdavi, Fatemeh; Mirjalali, Hamed; Niyyati, Maryam; Seyyed Tabaei, Seyyed Javad; Shamloo, Amir; Asadzadeh Aghdaei, Hamid.
Afiliação
  • Mahdavi F; Department of Medical Parasitology and Mycology, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Mirjalali H; Foodborne and Waterborne Diseases Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Niyyati M; Department of Medical Parasitology and Mycology, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Seyyed Tabaei SJ; Department of Medical Parasitology and Mycology, Faculty of Medicine, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
  • Shamloo A; Department of Mechanical Engineering, Sharif University of Technology, Tehran, Iran.
  • Asadzadeh Aghdaei H; Basic and Molecular Epidemiology of Gastrointestinal Disorders Research Center, Research Institute for Gastroenterology and Liver Diseases, Shahid Beheshti University of Medical Sciences, Tehran, Iran.
Food Waterborne Parasitol ; 35: e00225, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38523772
ABSTRACT
Enterocytozoon bieneusi is one of the most prevalent microsporidia species, responsible for more than 90% of human and animal microsporidiosis. Microsporidia species, particularly E. bieneusi, are frequently reported from waterborne and foodborne outbreaks. Therefore, early detection is crucial in clinics and outbreak investigations. This study aimed to design a loop-mediated isothermal amplification (LAMP) for rapid detection of E. bieneusi. Total DNA was extracted from 30 E. bieneusi -positive samples, which had been confirmed with nested PCR. LAMP primers were designed based on the identical fragment of small subunit ribosomal RNA (SSU rRNA) gene. LAMP reactions were performed at 63 °C for 60 min. The sensitivity and specificity of the assay were analyzed and the results of amplification were compared to real-time PCR. Our results showed that the LAMP assay successfully amplified 25/30 (83.3%) samples. The specificity results indicated no false positive with other microorganisms. Furthermore, the LAMP method exhibited a sensitivity (limit of detection, LoD) as low as 34 ag/µL of total DNA. Compared to the LAMP assay, real-time PCR was able to detect all 30 nested PCR-positive samples. Our findings showed that the LAMP assay was able to detect 83.3% of E. bieneusi-positive samples. Although the current assay was not able to detect all nested PCR-positive samples, the lack of need for specific instruments, rapid processes, and high specificity makes LAMP assay a suitable tool for screening.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article