Your browser doesn't support javascript.
loading
OCTA Signal Quality Augmentation Using the Isometric Handgrip Test to Maximize Vascular Flow (SQUEEZE): A Randomized Crossover Trial.
Trinh, Matt; Nam, Judy; Kumar, Meenakshi; Nivison-Smith, Lisa.
Afiliação
  • Trinh M; School of Optometry and Vision Science, University of New South Wales, Sydney, Australia.
  • Nam J; School of Optometry and Vision Science, University of New South Wales, Sydney, Australia.
  • Kumar M; School of Optometry and Vision Science, University of New South Wales, Sydney, Australia.
  • Nivison-Smith L; School of Optometry and Vision Science, University of New South Wales, Sydney, Australia.
Transl Vis Sci Technol ; 13(3): 22, 2024 Mar 01.
Article em En | MEDLINE | ID: mdl-38530302
ABSTRACT

Purpose:

To determine if performing the isometric handgrip test (IHGT) can augment optical coherence tomography angiography (OCTA) vascular signal quality in eyes with macular abnormalities.

Methods:

A randomized, single-blinded crossover trial was conducted including 36 participants with macular abnormalities, randomized to undergo OCTA with or without the IHGT, then crossed over to the alternate "intervention" after 1 minute. The primary outcome was OCTA signal quality after 1 minute of squeezing at 50% maximum grip strength. Secondary outcomes were other measures of vascular flow and systemic blood pressure (BP), also regressed against person- and eye-level covariables.

Results:

Primary analysis of OCTA signal quality with versus without the IHGT was nonsignificant (P = 0.73). Nested analyses showed that the IHGT resulted in increased OCTA B-scan retinal vascular flow signal (2.95 [-1.64 to 7.55] Δ%, P < 0.05) and increased systolic BP, diastolic BP, pulse pressure, and mean arterial pressure (4.94 [0.41 to 9.47] to 12.38 [8.01 to 16.75] mm Hg, P < 0.05). OCTA signal quality and en face vessel density and perfusion changes were associated with sex, refraction, race/ethnicity, and right-hand IHGT use (P < 0.05). Greater increases in systolic and diastolic BP and mean arterial pressure were generally associated with right-hand IHGT use and greater maximum grip strength (P < 0.09).

Conclusions:

The IHGT can temporarily increase OCTA B-scan retinal vascular flow signal in participants with macular abnormalities. IHGT-induced changes to systemic BP appear to be linked to absolute (rather than relative) grip strength, implying that the IHGT may be ineffective with low grip strength. Further research in larger populations is warranted. Translational Relevance This study provides early validation that the IHGT may augment OCTA output, which may lead to improved noninvasive detection of pathologic vascular changes.