Your browser doesn't support javascript.
loading
Dosimetric comparison between carotid-sparing IMRT and 3DCRT in early glottic cancer patients treated with definitive radiation therapy.
Kaur, Harkirat; Thakur, Niketa; Sharma, Ramita; Sudan, Meena; Jain, Neeraj; Kaur, Supreet; Lehal, Priyanka.
Afiliação
  • Kaur H; Department of Radiation Oncology, Patel Hospital, Civil Lines, Jalandhar, Punjab, India.
  • Thakur N; Department of Radiation Oncology, SGRD Institute of Medical Sciences and Research, Amritsar, Punjab, India.
  • Sharma R; Department of Radiation Oncology, SGRD Institute of Medical Sciences and Research, Amritsar, Punjab, India.
  • Sudan M; Department of Radiation Oncology, SGRD Institute of Medical Sciences and Research, Amritsar, Punjab, India.
  • Jain N; Department of Radiation Oncology, SGRD Institute of Medical Sciences and Research, Amritsar, Punjab, India.
  • Kaur S; Department of Radiation Oncology, SGRD Institute of Medical Sciences and Research, Amritsar, Punjab, India.
  • Lehal P; Department of Radiation Oncology, SGRD Institute of Medical Sciences and Research, Amritsar, Punjab, India.
J Cancer Res Ther ; 20(1): 327-332, 2024 Jan 01.
Article em En | MEDLINE | ID: mdl-38554342
ABSTRACT

BACKGROUND:

The purpose of this study was to evaluate the dosimetric benefits of carotid-sparing IMRT (intensity-modulated radiation therapy) over 3DCRT (three-dimensional conformal radiation therapy) in early glottic cancer patients. MATERIAL AND

METHODS:

Ten patients with histologically proven early-stage squamous cell cancer of glottis (T1N0), treated with definitive radiotherapy, were selected retrospectively for the dosimetric analysis. Patients were originally treated with 3DCRT technique. For comparison purpose, IMRT plans were generated for each patient. Dosimetric comparison was done between two techniques (IMRT and 3DCRT) in terms of PTV (planning target volume) coverage, HI (homogeneity index), CI (conformity index), and doses to right carotid artery, left carotid artery, and spinal cord.

RESULTS:

V95% for the PTV was higher in IMRT plans (98.26%) as compared to 3DCRT plans (95.12%) (P-value <0.001), whereas V105% for PTV was significantly higher in 3DCRT plans (16.77%) as compared to IMRT plans (0.32%) (P-value 0.11). In terms of both HI and CI, IMRT plans showed better conformity as compared to 3DCRT plans, with statistically significant difference. Both right and left carotid arteries' average mean and maximum doses were significantly lower in IMRT plans as compared to 3DCRT plans (P-value <0.001). IMRT plans resulted in significant carotid-sparing as compared to 3DCRT plans in terms of V35 and V50 (P-value <0.001).

CONCLUSION:

Carotid-sparing IMRT resulted in better PTV coverage and lower carotid artery dose as compared to 3DCRT in early glottic cancer patients.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Laríngeas / Radioterapia Conformacional / Radioterapia de Intensidade Modulada Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Neoplasias Laríngeas / Radioterapia Conformacional / Radioterapia de Intensidade Modulada Idioma: En Ano de publicação: 2024 Tipo de documento: Article