Your browser doesn't support javascript.
loading
Analysis of Serum Free Thyroxine Concentrations in Healthy Term Neonates Underlines Need for Local and Laboratory-Specific Reference Interval: A Systematic Review and Meta-Analysis of Individual Participant Data.
Lauffer, Peter; Heinen, Charlotte A; Goorsenberg, Annika W M; Malekzadeh, Arjan; Henneman, Peter; Heijboer, Annemieke C; Zwaveling-Soonawala, Nitash; Boelen, Anita; van Trotsenburg, A S Paul.
Afiliação
  • Lauffer P; Department of Pediatric Endocrinology, Emma Children's Hospital, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.
  • Heinen CA; Amsterdam Gastroenterology Endocrinology Metabolism, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.
  • Goorsenberg AWM; Department of Pediatric Endocrinology, Emma Children's Hospital, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.
  • Malekzadeh A; Department of Pediatric Endocrinology, Emma Children's Hospital, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.
  • Henneman P; Medical Library, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.
  • Heijboer AC; Department of Human Genetics, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.
  • Zwaveling-Soonawala N; Amsterdam Gastroenterology Endocrinology Metabolism, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.
  • Boelen A; Endocrine Laboratory, Amsterdam University Medical Centers, University of Amsterdam, Amsterdam, The Netherlands.
  • van Trotsenburg ASP; Endocrine Laboratory, Amsterdam University Medical Centers, VU University, Amsterdam, The Netherlands.
Thyroid ; 34(5): 559-565, 2024 May.
Article em En | MEDLINE | ID: mdl-38563802
ABSTRACT

Background:

Initial evaluation of the hypothalamus-pituitary-thyroid axis is done by measuring serum free thyroxine (fT4) and thyrotropin concentrations. For correct interpretation of these measurements, reliable age-specific reference intervals (RIs) are fundamental. Since neonatal fT4 RIs conforming to the Clinical and Laboratory Standards Institute guidelines are not available for all assays, we set out to create literature-based uniform age-specific neonatal fT4 RIs that may be used for every assay.

Methods:

For meta-analysis of individual participant fT4 concentrations, we systematically searched MEDLINE and Embase (search date December 6, 2023; PROSPERO registration CRD42016041871). We searched for studies reporting fT4 concentrations in healthy term newborns aged 2-27 days, born to mothers without thyroid disease in iodine-sufficient regions. Authors were invited to supply data. Due to standardization differences between assays, data could not be combined for meta-analysis directly, and we attempted to normalize the data using two distinct methods.

Results:

We obtained 4206 fT4 concentrations from 20 studies that used 13 different assays from 6 manufacturers. First, we set out to normalize fT4 data using the mean and standard deviation of (assay-specific) adult RIs. fT4 concentrations were transformed into Z-scores, assuming a normal distribution. Using a linear mixed-effects model (LMM), we still found a significant difference between fT4 concentration across studies (p < 0.001), after this normalization. As a second approach, we normalized the fT4 concentrations using data from a method/assay comparison study. We used the relationship between the Cobas assay and the other assays as a reference point to convert all values to Cobas values. However, this method also failed to produce consistent results, with significant differences between the normalized data (LMM p < 0.001).

Conclusions:

We conclude that our attempts at normalizing fT4 assay results were unsuccessful. Confounders related to our unsuccessful analysis may be assay related and/or biological. These findings have significant implications for patient care, since relying on RIs from literature may result in erroneous interpretation of results. Therefore, we strongly recommend to establish local RIs for accurate interpretation of serum fT4 concentrations in neonates.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tiroxina Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tiroxina Idioma: En Ano de publicação: 2024 Tipo de documento: Article