Comparing meibomian gland visibility on optical coherence tomography and Keratograph 5M images using objective and subjective grading methods.
Ravichandran, Swetha; Pucker, Andrew D.
Afiliação
  • Ravichandran S; School of Optometry, University of Alabama at Birmingham, Alabama, United States.
  • Pucker AD; School of Optometry, University of Alabama at Birmingham, Alabama, United States; Lexitas Pharma Services, Durham, NC, United States. Electronic address: andrew.pucker@lexitas.com.
Cont Lens Anterior Eye ; 47(3): 102162, 2024 Jun.
Article em En | MEDLINE | ID: mdl-38565442
ABSTRACT

PURPOSE:

To investigate if there is a visible difference in meibomian gland (MG) length between images captured with the Visante optical coherence tomography (OCT; wavelength = 1,310 nm) and the OCULUS Keratograph 5M (K5M; wavelength = 880 nm).

METHODS:

Adults between 18 and 40 years were recruited. Baseline dry eye disease was evaluated with the Standard Patient Evaluation of Eye Dryness (SPEED) and tear meniscus height and tear breakup time with the K5M. Right upper and lower eyelid MGs were imaged with the K5M and Visante OCT. Each image was graded with the 0 to 3 meiboscore scale. The central 5 MGs were evaluated with ImageJ for percent gland length visibility.

RESULTS:

Thirty participants were analyzed with a median (interquartile range [IQR]) age of 23.0 (5.0) years (53.3 % female). Overall, participants were asymptomatic and had normal tear films. Meiboscores based on K5M and Visante OCT was significantly different for the lower eyelid (0[1] vs 1[2]; p = 0.007) but not the upper eyelid (0[1] vs 0[1]; p = 1.00). The mean percent gland visibility of the upper eyelid (82.7[9.6] vs 75.2[13.5]; p < 0.001) and the lower eyelid (81.2[12.7] vs 64.1[17.6]; p < 0.001) were significantly greater on the Visante OCT than the K5M images, respectively.

CONCLUSION:

OCT images had significantly greater percent visible MG lengths than the K5M images. This suggests viable segments of the MGs may be missed with typical imaging, which may explain how it is possible that studies have found less post-treatment MG atrophy.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Lágrimas / Síndromes do Olho Seco / Tomografia de Coerência Óptica / Glândulas Tarsais Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Lágrimas / Síndromes do Olho Seco / Tomografia de Coerência Óptica / Glândulas Tarsais Idioma: En Ano de publicação: 2024 Tipo de documento: Article