Intravascular guide wire aspiration in a patient on extracorporeal membrane oxygenation: A case report.
Choi, Jae Ho; Yoo, Jae Hwa; Chang, Won Ho; Park, Young Woo; Kim, Hyun Jo; Oh, Hong Chul.
Afiliação
  • Choi JH; Department of Thoracic and Cardiovascular surgery, Soonchunhyang University Hospital Seoul, Seoul, Republic of Korea.
  • Yoo JH; Department of Anesthesiology and Pain Medicine, Soonchunhyang University Hospital Seoul, Seoul, Republic of Korea.
  • Chang WH; Department of Thoracic and Cardiovascular surgery, Soonchunhyang University Hospital Seoul, Seoul, Republic of Korea.
  • Park YW; Department of Thoracic and Cardiovascular surgery, Soonchunhyang University Hospital Seoul, Seoul, Republic of Korea.
  • Kim HJ; Department of Thoracic and Cardiovascular surgery, Soonchunhyang University Hospital Seoul, Seoul, Republic of Korea.
  • Oh HC; Department of Thoracic and Cardiovascular surgery, Soonchunhyang University Hospital Seoul, Seoul, Republic of Korea.
Medicine (Baltimore) ; 103(14): e37638, 2024 Apr 05.
Article em En | MEDLINE | ID: mdl-38579027
ABSTRACT
RATIONALE Guide wire aspiration during central venous catheter (CVC) insertion in a patient on extracorporeal membrane oxygenation (ECMO) is a very rare but dangerous complication. A guide wire aspirated inside the ECMO can cause thrombosis, the ECMO to break down or shut off, and unnecessary ECMO replacement. PATIENT CONCERNS A 58-year-old man was scheduled for venovenous ECMO for acute respiratory distress syndrome. After his vital signs stabilized, we inserted a CVC. During CVC insertion, the guide wire was aspirated into the ECMO venous line. INTERVENTION After confirming the guide wire inside the ECMO venous line, we replaced the entire ECMO circuit.

OUTCOMES:

ECMO was maintained for 57 days, and weaning was successful but the patient died 5 days afterward. LESSONS Care must be taken when inserting a CVC using a guide wire in ECMO patients the guide wire should not be inserted deeply, it should be secured during insertion, the ECMO venous cannula tip requires proper positioning, and ECMO flow should be temporarily reduced.