Your browser doesn't support javascript.
loading
Modeling of brain efflux: Constraints of brain surfaces.
Bork, Peter A R; Hauglund, Natalie L; Mori, Yuki; Møllgård, Kjeld; Hjorth, Poul G; Nedergaard, Maiken.
Afiliação
  • Bork PAR; Center for Translational Neuromedicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen 2200 Denmark.
  • Hauglund NL; Center for Translational Neuromedicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen 2200 Denmark.
  • Mori Y; Center for Translational Neuromedicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen 2200 Denmark.
  • Møllgård K; Department of Cellular and Molecular Medicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen 2200 Denmark.
  • Hjorth PG; Department of Applied Mathematics and Computer Science, Technical University of Denmark, Lyngby 2800 Denmark.
  • Nedergaard M; Center for Translational Neuromedicine, Faculty of Health and Medical Sciences, University of Copenhagen, Copenhagen 2200 Denmark.
Proc Natl Acad Sci U S A ; 121(16): e2318444121, 2024 Apr 16.
Article em En | MEDLINE | ID: mdl-38598340
ABSTRACT
Fluid efflux from the brain plays an important role in solute waste clearance. Current experimental approaches provide little spatial information, and data collection is limited due to short duration or low frequency of sampling. One approach shows tracer efflux to be independent of molecular size, indicating bulk flow, yet also decelerating like simple membrane diffusion. In an apparent contradiction to this report, other studies point to tracer efflux acceleration. We here develop a one-dimensional advection-diffusion model to gain insight into brain efflux principles. The model is characterized by nine physiological constants and three efflux parameters for which we quantify prior uncertainty. Using Bayes' rule and the two efflux studies, we validate the model and calculate data-informed parameter distributions. The apparent contradictions in the efflux studies are resolved by brain surface boundaries being bottlenecks for efflux. To critically test the model, a custom MRI efflux assay measuring solute dispersion in tissue and release to cerebrospinal fluid was employed. The model passed the test with tissue bulk flow velocities in the range 60 to 190 [Formula see text]m/h. Dimensional analysis identified three principal determinants of efflux, highlighting brain surfaces as a restricting factor for metabolite solute clearance.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Encéfalo Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Encéfalo Idioma: En Ano de publicação: 2024 Tipo de documento: Article