Your browser doesn't support javascript.
loading
Chemical shift-encoded MRI with compressed sensing combined with parallel imaging for proton density fat fraction measurement of the lumbar vertebral bone marrow.
Misaka, Tomofumi; Hashimoto, Yukihiko; Ashikaga, Ryuichiro; Ishida, Takayuki.
Afiliação
  • Misaka T; Department of Radiology, Kindai University Nara Hospital, Ikoma, Japan.
  • Hashimoto Y; Department of Medical Physics and Engineering, Graduate School of Medicine, Osaka University, Suita, Japan.
  • Ashikaga R; Department of Surgery, Tsuji Hospital, Osaka, Japan.
  • Ishida T; Department of Radiology, Kindai University Nara Hospital, Ikoma, Japan.
Medicine (Baltimore) ; 103(15): e37748, 2024 Apr 12.
Article em En | MEDLINE | ID: mdl-38608106
ABSTRACT
We aimed to investigate the accuracy of proton density fat fraction (PDFF) measurement of the lumbar vertebral bone marrow using chemical shift-encoded magnetic resonance imaging (CSE-MRI) with compressed sensing combined with parallel imaging (CSPI). This study recruited a commercially available phantom, and 43 patients. Fully sampled data without CSPI and under-sampled data with CSPI acceleration factors of 2.4, 3.6, and 4.8 were acquired using a 1.5T imaging system. The relationships between PDFF measurements obtained with the no-CSPI acquisition and those obtained with each CSPI acquisition were assessed using Pearson correlation coefficient (r), linear regression analyses, and Bland-Altman analysis. The intra- and inter-observer variabilities of the PDFF measurements were evaluated using the intraclass correlation coefficient. PDFF measurements obtained with all acquisitions showed a significant correlation and strong agreement with the reference PDFF measurement of the phantom. PDFF measurements obtained using CSE-MRI with and without CSPI were positively correlated (all acquisitions r = 0.99; P < .001). The mean bias was -0.31% to -0.17% with 95% limits of agreement within ±2.02%. The intra- and inter-observer agreements were excellent (intraclass correlation coefficient 0.988 and 0.981, respectively). A strong agreement and positive correlation were observed between the PDFF measurements obtained using CSE-MRI with and without CSPI. PDFF measurement of the lumbar vertebral bone marrow using CSE-MRI with CSPI can be acquired with a maximum reduction of approximately 75% in the acquisition time compared with a fully sampled acquisition.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Prótons / Medula Óssea Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Prótons / Medula Óssea Idioma: En Ano de publicação: 2024 Tipo de documento: Article