Your browser doesn't support javascript.
loading
In situ generated CdTe quantum dot-encapsulated hafnium polymer membrane to boost electrochemiluminescence analysis of tumor biomarkers.
Li, Haiyin; Wang, Zhixin; Li, Feng; Gai, Panpan.
Afiliação
  • Li H; College of Chemistry and Pharmaceutical Sciences, Qingdao Agricultural University, Qingdao, 266109, People's Republic of China.
  • Wang Z; Key Laboratory of Medicinal Chemistry and Molecular Diagnosis of the Ministry of Education, Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, Baoding, 071002, Hebei, People's Republic of China.
  • Li F; College of Chemistry and Pharmaceutical Sciences, Qingdao Agricultural University, Qingdao, 266109, People's Republic of China.
  • Gai P; College of Chemistry and Pharmaceutical Sciences, Qingdao Agricultural University, Qingdao, 266109, People's Republic of China.
Anal Bioanal Chem ; 416(21): 4769-4778, 2024 Sep.
Article em En | MEDLINE | ID: mdl-38676824
ABSTRACT
Exploring the construction of an interface with bright emission, fabulous stability, and good function to develop high-performance electrochemiluminescence (ECL) biosensors for tumor biomarkers is in high demand but faces a huge challenge. Herein, we report an oriented attachment and in situ self-assembling strategy for one-step fabrication of CdTe QD-encapsulated Hf polymer membrane onto an ITO surface (Hf-CP/CdTe QDs/APS/ITO). Hf-CP/CdTe QDs/APS/ITO is fascinating with excellent stability, high ECL emission, and specific adsorption toward ssDNA against dsDNA and mononucleotides (mNs). These interesting properties make it an ideal interface to rationally develop an immobilization-free ECL biosensor for cancer antigen 125 (CA125), used as a proof-of-concept analyte, based on target-aptamer recognition-promoted exonuclease III (Exo III)-assisted digestion. The recognition of ON by CA125 leads to the formation of CA125@ON, which hybridizes with Fc-ssDNA to switch Exo III-assisted digestion, decreasing the amount of Fc groups anchored onto the electrode's surface and blocking electron transfer. As compared to the case where CA125 was absent, significant ECL emission recovery is determined and relies on CA125 concentration. Thus, highly sensitive analysis of CA125 against other biomarkers was achieved with a limit of detection down to 2.57 pg/mL. We envision this work will provide a new path to develop ECL biosensors with excellent properties, which shows great potential for early and accurate diagnosis of cancer.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polímeros / Telúrio / Técnicas Biossensoriais / Biomarcadores Tumorais / Antígeno Ca-125 / Compostos de Cádmio / Pontos Quânticos / Técnicas Eletroquímicas / Medições Luminescentes Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Polímeros / Telúrio / Técnicas Biossensoriais / Biomarcadores Tumorais / Antígeno Ca-125 / Compostos de Cádmio / Pontos Quânticos / Técnicas Eletroquímicas / Medições Luminescentes Idioma: En Ano de publicação: 2024 Tipo de documento: Article