Your browser doesn't support javascript.
loading
Plastic scintillator-based dosimeters for ultra-high dose rate (UHDR) electron radiotherapy.
Ciarrocchi, E; Ravera, E; Cavalieri, A; Celentano, M; Del Sarto, D; Di Martino, F; Linsalata, S; Massa, M; Masturzo, L; Moggi, A; Morrocchi, M; Pensavalle, J H; Bisogni, M G.
Afiliação
  • Ciarrocchi E; University of Pisa, Department of Physics, Pisa, Italy; National Institute of Nuclear Physics, Section of Pisa, Pisa, Italy.
  • Ravera E; University of Pisa, Department of Physics, Pisa, Italy; National Institute of Nuclear Physics, Section of Pisa, Pisa, Italy.
  • Cavalieri A; University of Pisa, Department of Physics, Pisa, Italy; National Institute of Nuclear Physics, Section of Pisa, Pisa, Italy.
  • Celentano M; University of Pisa, Department of Physics, Pisa, Italy; Azienda ospedaliero-universitaria pisana, U.O. Fisica Sanitaria, Pisa, Italy; Centro Pisano ricerca e implementazione clinical Flash Radiotherapy (CPFR-CISUP), Pisa, Italy.
  • Del Sarto D; National Institute of Nuclear Physics, Section of Pisa, Pisa, Italy; Azienda ospedaliero-universitaria pisana, U.O. Fisica Sanitaria, Pisa, Italy; Centro Pisano ricerca e implementazione clinical Flash Radiotherapy (CPFR-CISUP), Pisa, Italy; University of Pisa, Center for Instrument Sharing of the U
  • Di Martino F; National Institute of Nuclear Physics, Section of Pisa, Pisa, Italy; Azienda ospedaliero-universitaria pisana, U.O. Fisica Sanitaria, Pisa, Italy; Centro Pisano ricerca e implementazione clinical Flash Radiotherapy (CPFR-CISUP), Pisa, Italy.
  • Linsalata S; Azienda ospedaliero-universitaria pisana, U.O. Fisica Sanitaria, Pisa, Italy.
  • Massa M; National Institute of Nuclear Physics, Section of Pisa, Pisa, Italy.
  • Masturzo L; University of Pisa, Department of Physics, Pisa, Italy; Azienda ospedaliero-universitaria pisana, U.O. Fisica Sanitaria, Pisa, Italy; Centro Pisano ricerca e implementazione clinical Flash Radiotherapy (CPFR-CISUP), Pisa, Italy; SIT Sordina IORT Technologies, Aprilia, Italy.
  • Moggi A; National Institute of Nuclear Physics, Section of Pisa, Pisa, Italy.
  • Morrocchi M; University of Pisa, Department of Physics, Pisa, Italy; National Institute of Nuclear Physics, Section of Pisa, Pisa, Italy. Electronic address: matteo.morrocchi@unipi.it.
  • Pensavalle JH; University of Pisa, Department of Physics, Pisa, Italy; Azienda ospedaliero-universitaria pisana, U.O. Fisica Sanitaria, Pisa, Italy; Centro Pisano ricerca e implementazione clinical Flash Radiotherapy (CPFR-CISUP), Pisa, Italy; SIT Sordina IORT Technologies, Aprilia, Italy.
  • Bisogni MG; University of Pisa, Department of Physics, Pisa, Italy; National Institute of Nuclear Physics, Section of Pisa, Pisa, Italy; Centro Pisano ricerca e implementazione clinical Flash Radiotherapy (CPFR-CISUP), Pisa, Italy.
Phys Med ; 121: 103360, 2024 May.
Article em En | MEDLINE | ID: mdl-38692114
ABSTRACT
This paper reports the development of dosimeters based on plastic scintillating fibers imaged by a charge-coupled device camera, and their performance evaluation through irradiations with the electron Flash research accelerator located at the Centro Pisano Flash Radiotherapy. The dosimeter prototypes were composed of a piece of plastic scintillating fiber optically coupled to a clear optical fiber which transported the scintillation signal to the readout systems (an imaging system and a photodiode). The following properties were tested linearity, capability to reconstruct the percentage depth dose curve in solid water and to sample in time the single beam pulse. The stem effect contribution was evaluated with three methods, and a proof-of-concept one-dimensional array was developed and tested for online beam profiling. Results show linearity up to 10 Gy per pulse, and good capability to reconstruct both the timing and spatial profiles of the beam, thus suggesting that plastic scintillating fibers may be good candidates for low-energy electron Flash dosimetry.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Plásticos / Dosagem Radioterapêutica / Contagem de Cintilação / Elétrons / Dosímetros de Radiação Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Plásticos / Dosagem Radioterapêutica / Contagem de Cintilação / Elétrons / Dosímetros de Radiação Idioma: En Ano de publicação: 2024 Tipo de documento: Article