Your browser doesn't support javascript.
loading
Which distribution to choose for deriving a species sensitivity distribution? Implications from analysis of acute and chronic ecotoxicity data.
Yanagihara, Miina; Hiki, Kyoshiro; Iwasaki, Yuichi.
Afiliação
  • Yanagihara M; KWR Water Research Institute, Groningenhaven 7, Nieuwegein 3433 PE, the Netherlands; Center for Marine Environmental Studies, Ehime University Bunkyo-cho 3, Matsuyama, Ehime 790-8577, Japan. Electronic address: Miina.Yanagihara@kwrwater.nl.
  • Hiki K; Health and Environmental Risk Division, National Institute for Environmental Studies, 16-2 Onogawa, Tsukuba, Ibaraki 305-8506, Japan. Electronic address: hiki.kyoshiro@nies.go.jp.
  • Iwasaki Y; Research Institute of Science for Safety and Sustainability, National Institute of Advanced Industrial Science and Technology (AIST), 16-1 Onogawa, Tsukuba, Ibaraki 305-8569, Japan. Electronic address: yuichi-iwasaki@aist.go.jp.
Ecotoxicol Environ Saf ; 278: 116379, 2024 Jun 15.
Article em En | MEDLINE | ID: mdl-38714082
ABSTRACT
Species sensitivity distributions (SSDs) estimated by fitting a statistical distribution to ecotoxicity data are indispensable tools used to derive the hazardous concentration for 5 % of species (HC5) and thereby a predicted no-effect concentration in environmental risk assessment. Whereas various statistical distributions are available for SSD estimation, the fundamental question of which statistical distribution should be used has received limited systematic analysis. We aimed to address this knowledge gap by applying four frequently used statistical distributions (log-normal, log-logistic, Burr type III, and Weibull distributions) to acute and chronic SSD estimation using aquatic toxicity data for 191 and 31 chemicals, respectively. Based on the differences in the corrected Akaike's information criterion (AICc) as well as visual inspection of the fitting of the lower tails of SSD curves, the log-normal SSD was generally better or equally good for the majority of chemicals examined. Together with the fact that the ratios of HC5 values of other alternative SSDs to those of log-normal SSDs generally fell within the range 0.1-10, our findings indicate that the log-normal distribution can be a reasonable first candidate for SSD derivation, which does not contest the existing widespread use of log-normal SSDs.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poluentes Químicos da Água Idioma: En Ano de publicação: 2024 Tipo de documento: Article