Improvement of a pharmaceutical powder mixing process in a tote blender via DEM simulations.
Benque, Benedict; Orefice, Luca; Forgber, Thomas; Habeler, Matthias; Schmid, Beate; Remmelgas, Johan; Khinast, Johannes.
Afiliação
  • Benque B; Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria. Electronic address: benedict.benque@rcpe.at.
  • Orefice L; Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria.
  • Forgber T; Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria.
  • Habeler M; Sandoz GmbH, Biochemiestrasse 10, 6250 Kundl, Austria.
  • Schmid B; Sandoz GmbH, Biochemiestrasse 10, 6250 Kundl, Austria.
  • Remmelgas J; Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria.
  • Khinast J; Research Center Pharmaceutical Engineering GmbH, Inffeldgasse 13, 8010 Graz, Austria; Institute of Process and Particle Engineering, TU Graz, Inffeldgasse 13, 8010 Graz, Austria.
Int J Pharm ; 658: 124224, 2024 Jun 10.
Article em En | MEDLINE | ID: mdl-38740105
ABSTRACT
An industrial-scale pharmaceutical powder blending process was studied via discrete element method (DEM) simulations. A DEM model of two active pharmaceutical ingredient (API) components and a combined excipient component was calibrated by matching the simulated response in a dynamic angle of repose tester to the experimentally observed response. A simulation of the 25-minute bin blending process predicted inhomogeneous API distributions along the rotation axis of the blending container. These concentration differences were confirmed experimentally in a production-scale mixing trial using high-performance liquid chromatography analysis of samples from various locations in the bin. Several strategies to improve the blend homogeneity were then studied using DEM simulations. Reversing the direction of rotation of the blender every minute was found to negligibly improve the blending performance. Introducing a baffle into the lid at a 45° angle to the rotation axis sped up the axial mixing and resulted in a better final blend uniformity. Alternatively, rotating the blending container 90° around the vertical axis five minutes prior to the process end was predicted to reduce axial segregation tendencies.