Your browser doesn't support javascript.
loading
Optical Nanosensor Passivation Enables Highly Sensitive Detection of the Inflammatory Cytokine Interleukin-6.
Gaikwad, Pooja; Rahman, Nazifa; Parikh, Rooshi; Crespo, Jalen; Cohen, Zachary; Williams, Ryan M.
Afiliação
  • Gaikwad P; Department of Biomedical Engineering, The City College of New York, New York, New York 10031, United States of America.
  • Rahman N; PhD Program in Chemistry, The Graduate Center of The City University of New York, New York, New York 10016, United States of America.
  • Parikh R; Department of Biomedical Engineering, The City College of New York, New York, New York 10031, United States of America.
  • Crespo J; Department of Biomedical Engineering, The City College of New York, New York, New York 10031, United States of America.
  • Cohen Z; Department of Biomedical Engineering, The City College of New York, New York, New York 10031, United States of America.
  • Williams RM; Department of Biomedical Engineering, The City College of New York, New York, New York 10031, United States of America.
ACS Appl Mater Interfaces ; 16(21): 27102-27113, 2024 May 29.
Article em En | MEDLINE | ID: mdl-38745465
ABSTRACT
Interleukin-6 (IL-6) is known to play a critical role in the progression of inflammatory diseases such as cardiovascular disease, cancer, sepsis, viral infection, neurological disease, and autoimmune diseases. Emerging diagnostic and prognostic tools, such as optical nanosensors, experience challenges in translation to the clinic in part due to protein corona formation, dampening their selectivity and sensitivity. To address this problem, we explored the rational screening of several classes of biomolecules to be employed as agents in noncovalent surface passivation as a strategy to screen interference from nonspecific proteins. Findings from this screening were applied to the detection of IL-6 by a fluorescent-antibody-conjugated single-walled carbon nanotube (SWCNT)-based nanosensor. The IL-6 nanosensor exhibited highly sensitive and specific detection after passivation with a polymer, poly-l-lysine, as demonstrated by IL-6 detection in human serum within a clinically relevant range of 25 to 25,000 pg/mL, exhibiting a limit of detection over 3 orders of magnitude lower than prior antibody-conjugated SWCNT sensors. This work holds potential for the rapid and highly sensitive detection of IL-6 in clinical settings with future application to other cytokines or disease-specific biomarkers.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Interleucina-6 / Nanotubos de Carbono Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Interleucina-6 / Nanotubos de Carbono Idioma: En Ano de publicação: 2024 Tipo de documento: Article