Your browser doesn't support javascript.
loading
Rapid screening of drugs in environmental water using metal organic framework/Ti3C2Tx composite coated blade spray-mass spectrometry.
Hu, Kai; Zhou, Wei; Yang, Cheng; Wang, Yuanpeng; Jiang, Runshan Will; Zhang, Zhenqiang; Pawliszyn, Janusz.
Afiliação
  • Hu K; Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada; Academy of Chinese Medical Sciences, Henan University of Chinese Medicine, Zhengzhou 450046, China. Electronic address: hk5268@126.com.
  • Zhou W; Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
  • Yang C; Academy of Chinese Medical Sciences, Henan University of Chinese Medicine, Zhengzhou 450046, China.
  • Wang Y; Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
  • Jiang RW; Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada.
  • Zhang Z; Academy of Chinese Medical Sciences, Henan University of Chinese Medicine, Zhengzhou 450046, China.
  • Pawliszyn J; Department of Chemistry, University of Waterloo, Waterloo, ON N2L 3G1, Canada. Electronic address: janusz@uwaterloo.ca.
J Hazard Mater ; 472: 134609, 2024 Jul 05.
Article em En | MEDLINE | ID: mdl-38759280
ABSTRACT
Simultaneous rapid screening of multiple drugs of abuse in environmental water facilitates effective monitoring and trend assessments. Herein, a novel porphyrin-based metal organic frameworks modified Ti3C2Tx nanosheets (Cu-TCPP/Ti3C2Tx) composite was prepared and utilized as solid-phase microextraction (SPME) coating for the simultaneous analysis of 21 drugs from water samples. The composite was embedded with matrix-compatible polyacrylonitrile binder to prepare a coated blade with thin and uniform coating layer. Ambient mass spectrometry (MS) technique was used to create a coated blade spray-MS (CBS-MS) method for the quantitative determination of drugs in water samples. High throughput and automated sample preparation were achieved with the use of a Concept 96-well plate system, enabling analysis of 21 drugs of abuse within 1 min per sample, while using only 8 µL of organic solvent for desorption and CBS-MS detection. The developed method showed favorable linearity (R2 ≥ 0.9983) in the range of 0.05 to 10 ng mL-1, low limits of detection (1.5-9.0 ng L-1), sufficient recovery (67.6-133.2%), as well as satisfactory precision (RSDs≤13.5%). This study not only delivers a novel and efficient SPME coating composite, but also demonstrates the excellent performance of a high-throughput, efficient, and green analytical method for determination of drugs in environmental water.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Poluentes Químicos da Água / Microextração em Fase Sólida / Estruturas Metalorgânicas Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Espectrometria de Massas / Poluentes Químicos da Água / Microextração em Fase Sólida / Estruturas Metalorgânicas Idioma: En Ano de publicação: 2024 Tipo de documento: Article