Electrocardiogram-based prediction of conduction disturbances after transcatheter aortic valve replacement with convolutional neural network.
Jia, Yuheng; Li, Yiming; Luosang, Gaden; Wang, Jianyong; Peng, Gang; Pu, Xingzhou; Jiang, Weili; Li, Wenjian; Zhao, Zhengang; Peng, Yong; Feng, Yuan; Wei, Jiafu; Xu, Yuanning; Liu, Xingbin; Yi, Zhang; Chen, Mao.
Afiliação
  • Jia Y; Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China.
  • Li Y; Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China.
  • Luosang G; Machine Intelligence Laboratory, College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, P. R. China.
  • Wang J; Department of Information Science and Technology, Tibet University, No.10 Zangda East Road, Lhasa 850000, Tibet, P. R. China.
  • Peng G; Machine Intelligence Laboratory, College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, P. R. China.
  • Pu X; Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China.
  • Jiang W; Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China.
  • Li W; Machine Intelligence Laboratory, College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, P. R. China.
  • Zhao Z; Machine Intelligence Laboratory, College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, P. R. China.
  • Peng Y; Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China.
  • Feng Y; Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China.
  • Wei J; Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China.
  • Xu Y; Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China.
  • Liu X; Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China.
  • Yi Z; Department of Cardiology, West China Hospital, Sichuan University, No.37 Guoxue Street, Chengdu 610041, P. R. China.
  • Chen M; Machine Intelligence Laboratory, College of Computer Science, Sichuan University, No.24 South Section 1, Yihuan Road, Chengdu 610065, P. R. China.
Eur Heart J Digit Health ; 5(3): 219-228, 2024 May.
Article em En | MEDLINE | ID: mdl-38774374
ABSTRACT

Aims:

Permanent pacemaker implantation and left bundle branch block are common complications after transcatheter aortic valve replacement (TAVR) and are associated with impaired prognosis. This study aimed to develop an artificial intelligence (AI) model for predicting conduction disturbances after TAVR using pre-procedural 12-lead electrocardiogram (ECG) images. Methods and

results:

We collected pre-procedural 12-lead ECGs of patients who underwent TAVR at West China Hospital between March 2016 and March 2022. A hold-out testing set comprising 20% of the sample was randomly selected. We developed an AI model using a convolutional neural network, trained it using five-fold cross-validation and tested it on the hold-out testing cohort. We also developed and validated an enhanced model that included additional clinical features. After applying exclusion criteria, we included 1354 ECGs of 718 patients in the study. The AI model predicted conduction disturbances in the hold-out testing cohort with an area under the curve (AUC) of 0.764, accuracy of 0.743, F1 score of 0.752, sensitivity of 0.876, and specificity of 0.624, based solely on pre-procedural ECG images. The performance was better than the Emory score (AUC = 0.704), as well as the logistic (AUC = 0.574) and XGBoost (AUC = 0.520) models built with previously identified high-risk ECG patterns. After adding clinical features, there was an increase in the overall performance with an AUC of 0.779, accuracy of 0.774, F1 score of 0.776, sensitivity of 0.794, and specificity of 0.752.

Conclusion:

Artificial intelligence-enhanced ECGs may offer better predictive value than traditionally defined high-risk ECG patterns.