Development of a NiFe2O4 covalent organic framework based magnetic solid-phase extraction approach for specific capture of quinolones in animal innards prior to UHPLC-Q-Orbitrap HRMS detection.
Lin, Shumin; Lv, Yun-Kai; Zhu, Aixue; Su, Ming; Li, Xiliang; Liang, Shu-Xuan.
Afiliação
  • Lin S; Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, Baoding 071002, PR China; Analysis and Testing Center, Inner Mongolia University of Science and Technology, Baotou 014010, PR China.
  • Lv YK; Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, Baoding 071002, PR China; State Key Laboratory of New Pharmaceutical Preparations and Excipients, Baoding 071002, PR China.
  • Zhu A; Large Scale Instruments Shared Service Platform, Hebei University, Baoding 071002, PR China.
  • Su M; Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, Baoding 071002, PR China; State Key Laboratory of New Pharmaceutical Preparations and Excipients, Baoding 071002, PR China.
  • Li X; School of Public Health, Hebei University, Baoding 071002, China.
  • Liang SX; Key Laboratory of Analytical Science and Technology of Hebei Province, College of Chemistry and Materials Science, Hebei University, Baoding 071002, PR China; State Key Laboratory of New Pharmaceutical Preparations and Excipients, Baoding 071002, PR China. Electronic address: liangsx168@126.com.
Food Chem ; 454: 139796, 2024 Oct 01.
Article em En | MEDLINE | ID: mdl-38797102
ABSTRACT
This study aimed to present a selective and effective method for analyzing quinolones (QNs) in food matrix. Herein, a NiFe2O4-based magnetic sodium disulfonate covalent organic framework (NiFe2O4/COF) was prepared using a simple solvent-free grinding method, and was adopted as a selective adsorbent for magnetic solid phase extraction of QNs. Coupled with UHPLC-Q-Orbitrap HRMS, an efficient method for simultaneous detection of 18 kinds of QNs was established. The method exhibited good linearity (0.01-100 ng g-1), high sensitivity (LODs ranging from 0.0011 to 0.0652 ng g-1) and precision (RSDs below 9.5%). Successful extraction of QNs from liver and kidney samples was achieved with satisfactory recoveries ranging from 82.2% to 108.4%. The abundant sulfonate functional groups on NiFe2O4/COF facilitated strong affinity to QNs through electrostatic and hydrogen bonding interactions. The proposed method provides a new idea for the extraction of contaminants with target selectivity.