Your browser doesn't support javascript.
loading
Evaluating the between-day reliability and likelihood of change of a test battery incorporating vastus lateralis muscle thickness, ankle-brachial pressure index, maximal voluntary torque, and six-minute walk test in patients with claudication.
Parkington, Thomas; Broom, David; Maden-Wilkinson, Thomas; Nawaz, Shah; Klonizakis, Markos.
Afiliação
  • Parkington T; Physical Activity, Wellness and Public Health Research Group, School of Sport and Physical Activity, Sheffield Hallam University, Sheffield, UK.
  • Broom D; Centre for Physical Activity, Sport and Exercise Sciences, Coventry University, Coventry, UK.
  • Maden-Wilkinson T; Physical Activity, Wellness and Public Health Research Group, School of Sport and Physical Activity, Sheffield Hallam University, Sheffield, UK.
  • Nawaz S; Sheffield Vascular Institute, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK.
  • Klonizakis M; Lifestyle, Exercise and Nutrition Improvement Research Group, Department of Nursing and Midwifery, Sheffield Hallam University, Sheffield, UK.
Vascular ; : 17085381241257735, 2024 May 28.
Article em En | MEDLINE | ID: mdl-38807381
ABSTRACT

OBJECTIVE:

The study aims to evaluate the between-day reliability of a proposed test battery for patients with claudication that can be used for monitoring the effectiveness of exercise interventions and other therapeutic strategies tailored to this patient population.

METHODS:

Twenty-five men with claudication were recruited. The test battery consisted of the Vastus Lateralis muscle thickness (VL-MT), ankle-brachial pressure index (ABI), unilateral isometric knee extension maximal voluntary torque (MVT) and 6-minute walk test (6MWT). A single investigator conducted the tests for each patient on two separate testing sessions (T1 and T2) 5-7 days apart.

RESULTS:

Good to excellent reliability was observed for VL-MT (ICC = 0.95, 95% LOA = ±3.10 mm, SEM = 0.81 mm), ABI (ICC = 0.97, 95% LOA = ±0.10, SEM = 0.02), MVT (ICC = 0.97, 95% LOA = ±24.0 N·m, SEM = 6.31 N·m), 6MWT distance (ICC = 0.99, 95% LOA = ±39.6 m, SEM = 11.0 m), 6MWT time to claudication (ICC = 0.99, 95% LOA = ±30.8 s, SEM = 7.8 s), and 6MWT ratings of pain (ICC = 0.87, 95% LOA = ±2.4 CR-10+, SEM = 0.7 CR-10+ ). Analysis derived from reliability data indicates a change of 1.4 mm for VL-MT, 0.14 for ABI, 12 N·m for MVT, 25 m for 6MWT distance, 15 s for 6MWT time to claudication and 1 CR-10+ for 6MWT ratings of pain is required to be interpreted as the minimum 'likely' change (76% chance).

CONCLUSIONS:

The test battery provides a reliable assessment of patients with claudication and can be widely used to evaluate the effects of exercise programmes and other therapeutic interventions. For the individual, changes in VL-MT, ABI, MVT, and 6MWT greater than the minimum likely change as a result of an exercise programme or an intervention are likely changes and less influenced by error associated with the test.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article