Your browser doesn't support javascript.
loading
Unintended and ectopic pregnancy in woman with iud translocation with history of two times previous cesarean section and history of spontaneous abortion: Case report.
Marlina, Dina; Tjandraprawira, Kevin; Aziz, Muhammad Alamsyah.
Afiliação
  • Marlina D; Department of Obstetrics and Gynecology, Faculty of Medicine, Universitas Padjadjaran-Dr. Hasan Sadikin General Hospital, Bandung, Indonesia.
  • Sutrisno; Department of Obstetrics and Gynecology, Faculty of Medicine, General Soedirman University-Prof. Dr. Margono Soekardjo Hospital, Purwokerto, Indonesia.
  • Tjandraprawira K; Department of Obstetrics and Gynecology, Faculty of Medicine, Universitas Padjadjaran-Dr. Hasan Sadikin General Hospital, Bandung, Indonesia.
  • Aziz MA; Department of Obstetrics and Gynecology, Faculty of Medicine, Universitas Padjadjaran-Dr. Hasan Sadikin General Hospital, Bandung, Indonesia.
SAGE Open Med Case Rep ; 12: 2050313X241258840, 2024.
Article em En | MEDLINE | ID: mdl-38812838
ABSTRACT
Intrauterine device is a widely used contraceptive method. However, it may translocate to other sites within the pelvic cavity, including the intestines and the bladder. This contraceptive method has failure rate between 1 and 3 out of 100 women/year. The use of intrauterine device also slightly increases the risk of ectopic pregnancy upon its failure. The combination of intrauterine device translocation and contraceptive failure is rare. We present such a case. A 29-year-old woman (Gravida 4, Para 2) presented with a complaint of abdominal pain and presence of blood spotting over the last 7 h. She tested positive for pregnancy. Upon arrival, her vital signs were normal, but she was moderately obese with a body mass index (BMI) of 38.8 kg/m2. She displayed tenderness during abdominal examination and cervical motion tenderness. Her blood test results showed no significant abnormalities. Abdominal ultrasound revealed a translocated part of intrauterine device to the cervix and transvaginal ultrasound confirmed the presence of a hypoechoic complex structure in the left adnexa, measuring 53 mm, alongside free fluid in Morrison's pouch. An emergency laparotomy was performed, revealing a normal uterus and a ruptured left fallopian tube with approximately 800 cc of blood in the abdomen.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article