Your browser doesn't support javascript.
loading
Toward a disruptive, minimally invasive small finger joint implant concept: Cellular and molecular interactions with materials in vivo.
Ben Amara, Heithem; Farjam, Pardis; Lutz, Theresa M; Omar, Omar; Palmquist, Anders; Lieleg, Oliver; Browne, Martin; Taylor, Andy; Verkerke, Gijsbertus J; Rouwkema, Jeroen; Thomsen, Peter.
Afiliação
  • Ben Amara H; Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden.
  • Farjam P; Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, the Netherlands.
  • Lutz TM; School of Engineering and Design, Department of Materials Engineering, Technical University of Munich, Munich, Germany.
  • Omar O; Department of Biomedical Dental Sciences, College of Dentistry, Imam Abdulrahman bin Faisal University, Dammam, Saudi Arabia.
  • Palmquist A; Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden.
  • Lieleg O; School of Engineering and Design, Department of Materials Engineering, Technical University of Munich, Munich, Germany.
  • Browne M; Bioengineering Science Research Group, School of Engineering, University of Southampton, Southampton, UK.
  • Taylor A; Aurora Medical Ltd, Chichester, UK.
  • Verkerke GJ; Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, the Netherlands.
  • Rouwkema J; Department of Biomechanical Engineering, Faculty of Engineering Technology, University of Twente, Enschede, the Netherlands.
  • Thomsen P; Department of Biomaterials, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Sweden. Electronic address: peter.thomsen@biomaterials.gu.se.
Acta Biomater ; 183: 130-145, 2024 Jul 15.
Article em En | MEDLINE | ID: mdl-38815684
ABSTRACT
Osteoarthritis (OA) poses significant therapeutic challenges, particularly OA that affects the hand. Currently available treatment strategies are often limited in terms of their efficacy in managing pain, regulating invasiveness, and restoring joint function. The APRICOTⓇ implant system developed by Aurora Medical Ltd (Chichester, UK) introduces a minimally invasive, bone-conserving approach for treating hand OA (https//apricot-project.eu/). By utilizing polycarbonate urethane (PCU), this implant incorporates a caterpillar track-inspired design to promote the restoration of natural movement to the joint. Surface modifications of PCU have been proposed for the biological fixation of the implant. This study investigated the biocompatibility of PCU alone or in combination with two surface modifications, namely dopamine-carboxymethylcellulose (dCMC) and calcium-phosphate (CaP) coatings. In a rat soft tissue model, native and CaP-coated PCU foils did not increase cellular migration or cytotoxicity at the implant-soft tissue interface after 3 d, showing gene expression of proinflammatory cytokines similar to that in non-implanted sham sites. However, dCMC induced an amplified initial inflammatory response that was characterized by increased chemotaxis and cytotoxicity, as well as pronounced gene activation of proinflammatory macrophages and neoangiogenesis. By 21 d, inflammation subsided in all the groups, allowing for implant encapsulation. In a rat bone model, 6 d and 28 d after release of the periosteum, all implant types were adapted to the bone surface with a surrounding fibrous capsule and no protracted inflammatory response was observed. These findings demonstrated the biocompatibility of native and CaP-coated PCU foils as components of APRICOTⓇ implants. STATEMENT OF

SIGNIFICANCE:

Hand osteoarthritis treatments require materials that minimize irritation of the delicate finger joints. Differing from existing treatments, the APRICOTⓇ implant leverages polycarbonate urethane (PCU) for minimally invasive joint replacement. This interdisciplinary, preclinical study investigated the biocompatibility of thin polycarbonate urethane (PCU) foils and their surface modifications with calcium-phosphate (CaP) or dopamine-carboxymethylcellulose (dCMC). Cellular and morphological analyses revealed that both native and Ca-P coated PCU elicit transient inflammation, similar to sham sites, and a thin fibrous encapsulation in soft tissues and on bone surfaces. However, dCMC surface modification amplified initial chemotaxis and cytotoxicity, with pronounced activation of proinflammatory and neoangiogenesis genes. Therefore, native and CaP-coated PCU possess sought-for biocompatible properties, crucial for patient safety and performance of APRICOTⓇ implant.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fosfatos de Cálcio Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fosfatos de Cálcio Idioma: En Ano de publicação: 2024 Tipo de documento: Article