Your browser doesn't support javascript.
loading
A PEDOT: PSS/GO fiber microelectrode fabricated by microfluidic spinning for dopamine detection in human serum and PC12 cells.
Zhao, Zexu; Hou, Yang; Zhang, Hao; Guo, Jiahao; Wang, Jinyi.
Afiliação
  • Zhao Z; Colleges of Chemistry and Pharmacy, Northwest A&F University, Yangling, 712100, Shaanxi, People's Republic of China.
  • Hou Y; Colleges of Chemistry and Pharmacy, Northwest A&F University, Yangling, 712100, Shaanxi, People's Republic of China.
  • Zhang H; Colleges of Chemistry and Pharmacy, Northwest A&F University, Yangling, 712100, Shaanxi, People's Republic of China.
  • Guo J; Colleges of Chemistry and Pharmacy, Northwest A&F University, Yangling, 712100, Shaanxi, People's Republic of China.
  • Wang J; Colleges of Chemistry and Pharmacy, Northwest A&F University, Yangling, 712100, Shaanxi, People's Republic of China. jywang@nwsuaf.edu.cn.
Mikrochim Acta ; 191(6): 362, 2024 06 01.
Article em En | MEDLINE | ID: mdl-38822867
ABSTRACT
Rapid and accurate in situ determination of dopamine is of great significance in the study of neurological diseases. In this work, poly (3,4-ethylenedioxythiophene) poly (styrenesulfonic acid) (PEDOT PSS)/graphene oxide (GO) fibers were fabricated by an effective method based on microfluidic wet spinning technology. The composite microfibers with stratified and dense arrangement were continuously prepared by injecting PEDOT PSS and GO dispersion solutions into a microfluidic chip. PEDOT PSS/GO fiber microelectrodes with high electrochemical activity and enhanced electrochemical oxidation activity of dopamine were constructed by controlling the structure composition of the microfibers with varying flow rate. The fabricated fiber microelectrode had a low detection limit (4.56 nM) and wide detection range (0.01-8.0 µM) for dopamine detection with excellent stability, repeatability, and reproducibility. In addition, the PEDOT PSS/GO fiber microelectrode prepared was successfully used for the detection of dopamine in human serum and PC12 cells. The strategy for the fabrication of multi-component fiber microelectrodes is a new and effective approach for monitoring the intercellular neurotransmitter dopamine and has high potential as an implantable neural microelectrode.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poliestirenos / Dopamina / Grafite / Microeletrodos Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Poliestirenos / Dopamina / Grafite / Microeletrodos Idioma: En Ano de publicação: 2024 Tipo de documento: Article