Your browser doesn't support javascript.
loading
Cardiac Health Assessment Using a Wearable Device Before and After Transcatheter Aortic Valve Implantation: Prospective Study.
Eerdekens, Rob; Zelis, Jo; Ter Horst, Herman; Crooijmans, Caia; van 't Veer, Marcel; Keulards, Danielle; Kelm, Marcus; Archer, Gareth; Kuehne, Titus; Brueren, Guus; Wijnbergen, Inge; Johnson, Nils; Tonino, Pim.
Afiliação
  • Eerdekens R; Department of Cardiology, Catharina Hospital Eindhoven, Eindhoven, Netherlands.
  • Zelis J; Department of Cardiology, Catharina Hospital Eindhoven, Eindhoven, Netherlands.
  • Ter Horst H; Philips Research Department, Eindhoven, Netherlands.
  • Crooijmans C; Department of Cardiology, RadboudUMC, Nijmegen, Netherlands.
  • van 't Veer M; Department of Cardiology, Catharina Hospital Eindhoven, Eindhoven, Netherlands.
  • Keulards D; Department of Biomedical Engineering, Eindhoven University of Technology, Eindhoven, Netherlands.
  • Kelm M; Department of Cardiology, Catharina Hospital Eindhoven, Eindhoven, Netherlands.
  • Archer G; Deutsches Herzzentrum der Charité, Institute of Computer-assisted Cardiovascular Medicine, Berlin, Germany.
  • Kuehne T; Department of Cardiology, Sheffield Teaching Hospital, Sheffield, United Kingdom.
  • Brueren G; Deutsches Herzzentrum der Charité, Institute of Computer-assisted Cardiovascular Medicine, Berlin, Germany.
  • Wijnbergen I; Department of Cardiology, Catharina Hospital Eindhoven, Eindhoven, Netherlands.
  • Johnson N; Department of Cardiology, Catharina Hospital Eindhoven, Eindhoven, Netherlands.
  • Tonino P; Weatherhead PET Imaging Center for Preventing and Reversing Atherosclerosis, Houston, TX, United States.
JMIR Mhealth Uhealth ; 12: e53964, 2024 Jun 03.
Article em En | MEDLINE | ID: mdl-38832585
ABSTRACT

Background:

Due to aging of the population, the prevalence of aortic valve stenosis will increase drastically in upcoming years. Consequently, transcatheter aortic valve implantation (TAVI) procedures will also expand worldwide. Optimal selection of patients who benefit with improved symptoms and prognoses is key, since TAVI is not without its risks. Currently, we are not able to adequately predict functional outcomes after TAVI. Quality of life measurement tools and traditional functional assessment tests do not always agree and can depend on factors unrelated to heart disease. Activity tracking using wearable devices might provide a more comprehensive assessment.

Objective:

This study aimed to identify objective parameters (eg, change in heart rate) associated with improvement after TAVI for severe aortic stenosis from a wearable device.

Methods:

In total, 100 patients undergoing routine TAVI wore a Philips Health Watch device for 1 week before and after the procedure. Watch data were analyzed offline-before TAVI for 97 patients and after TAVI for 75 patients.

Results:

Parameters such as the total number of steps and activity time did not change, in contrast to improvements in the 6-minute walking test (6MWT) and physical limitation domain of the transformed WHOQOL-BREF questionnaire.

Conclusions:

These findings, in an older TAVI population, show that watch-based parameters, such as the number of steps, do not change after TAVI, unlike traditional 6MWT and QoL assessments. Basic wearable device parameters might be less appropriate for measuring treatment effects from TAVI.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Substituição da Valva Aórtica Transcateter / Dispositivos Eletrônicos Vestíveis Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Substituição da Valva Aórtica Transcateter / Dispositivos Eletrônicos Vestíveis Idioma: En Ano de publicação: 2024 Tipo de documento: Article