Your browser doesn't support javascript.
loading
A novel standard-free detection of adulteration method for sildenafil derivatives in dietary supplements.
Lv, Diya; Wang, Dongyao; Li, Dan; Guo, Dandan; Qi, Minyu; Zhang, Ying; Chai, Yifeng; Chen, Xiaofei; Cao, Yan.
Afiliação
  • Lv D; Shanghai Key Laboratory for Pharmaceutical Metabolite Research, School of Pharmacy, Naval Medical University, Shanghai, China.
  • Wang D; Shanghai Key Laboratory for Pharmaceutical Metabolite Research, School of Pharmacy, Naval Medical University, Shanghai, China.
  • Li D; Eastern Hepatobiliary Surgery Institute, Naval Medical University, Shanghai, China.
  • Guo D; Shanghai Key Laboratory for Pharmaceutical Metabolite Research, School of Pharmacy, Naval Medical University, Shanghai, China.
  • Qi M; Shanghai Key Laboratory for Pharmaceutical Metabolite Research, School of Pharmacy, Naval Medical University, Shanghai, China.
  • Zhang Y; Shanghai Key Laboratory for Pharmaceutical Metabolite Research, School of Pharmacy, Naval Medical University, Shanghai, China.
  • Chai Y; Shanghai Key Laboratory for Pharmaceutical Metabolite Research, School of Pharmacy, Naval Medical University, Shanghai, China.
  • Chen X; Shanghai Key Laboratory for Pharmaceutical Metabolite Research, School of Pharmacy, Naval Medical University, Shanghai, China.
  • Cao Y; Shanghai Key Laboratory for Pharmaceutical Metabolite Research, School of Pharmacy, Naval Medical University, Shanghai, China.
Biomed Chromatogr ; 38(8): e5925, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38837800
ABSTRACT
The rapid and accurate detection of illegal adulteration of chemical drugs into dietary supplements is a big challenge in the food chemistry field. Detection of compounds without a standard reference is even more difficult; however, this is a common situation. Here in this study, a novel "standard-free detection of adulteration" (SFDA) method was proposed and phosphodiesterase-5 inhibitor derivatives were used as an example to figure out the possibility and reliability of this SFDA method. After analysis by quadrupole coupled time of flight-tandem mass spectrometry detection and multivariable statistics, six common fragment ions were chosen to indicate whether adulteration was present or not, while 20 characteristic fragment ions indicated whether adulteration was by nitrogen-containing heterocycles or by anilines. Furthermore, the quantitative methods were conducted by high-performance liquid chromatography-tandem mass spectrometry. In a word, this strategy allows for a quick determination of dietary supplement adulteration without any need for standard materials, improving the efficacy of food safety testing.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Contaminação de Medicamentos / Suplementos Nutricionais / Espectrometria de Massas em Tandem / Citrato de Sildenafila Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Contaminação de Medicamentos / Suplementos Nutricionais / Espectrometria de Massas em Tandem / Citrato de Sildenafila Idioma: En Ano de publicação: 2024 Tipo de documento: Article