Your browser doesn't support javascript.
loading
Radiation doses and diagnostic reference levels for common CT scans in adults in Northwest region of Iran.
Mardfar, Sina; Ghaziyani, Mona Fazel; Mortezazadeh, Tohid; Zamani, Hamed; Rahimiyan, Melika; Khezerloo, Davood.
Afiliação
  • Mardfar S; Department of Radiology, Faculty of Allied Medical Sciences, Tabriz University of Medical Science, Tabriz, Iran.
  • Ghaziyani MF; Department of Radiology, Faculty of Allied Medical Sciences, Tabriz University of Medical Science, Tabriz, Iran.
  • Mortezazadeh T; Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran.
  • Zamani H; Department of Medical Physics, Faculty of Medicine, Tabriz University of Medical Sciences, Tabriz, Iran.
  • Rahimiyan M; Department of Radiology, Faculty of Allied Medical Sciences, Tabriz University of Medical Science, Tabriz, Iran.
  • Khezerloo D; Department of Radiology, Faculty of Allied Medical Sciences, Tabriz University of Medical Science, Tabriz, Iran. khezerlood@tbzmed.ac.ir.
Article em En | MEDLINE | ID: mdl-38839606
ABSTRACT
This study aims to estimate organ dose and cancer risks, establish region-specific diagnostic reference levels (DRLs), and determine achievable doses (ADs) for common CT procedures in adults in the northwest of Iran. Effective and organ doses were estimated using VirtualDoseCT software in a sample of 480 adult patients who underwent head, sinus, chest, and abdomen-pelvis (AP) CT scans. The guidelines provided by the BEIR VII report were utilized to estimate cancer risks. Effective and organ doses for specific procedures were determined, with the highest mean organ dose being observed in the brain during head CT examinations, with a value of 54.02 mGy. It was observed that the lungs in chest examinations and the colon in AP examinations had the highest risk of cancer, with rates of 30.72 and 21.37 per 100,000 persons, respectively. Higher cancer risk values were generally exhibited by females compared to males. The DRLs for common CT examinations were established as follows Head CT (CTDIvol 41 mGy, DLP 760 mGy cm), Sinus CT (CTDIvol 16 mGy, DLP 261 mGy cm), Chest CT (CTDIvol 8 mGy, DLP 287 mGy cm), and AP CT (CTDIvol 9 mGy, DLP 508 mGy cm). Significant variations in dose distribution among facilities were identified, indicating the need for optimization. The study highlights the importance of minimizing radiation exposure to critical organs and promoting patient safety in CT examinations. The establishment of region-specific DRLs and ADs can help optimize radiation doses and reduce cancer risks for patients.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article