Your browser doesn't support javascript.
loading
Development and application of a CNT-Ag-Cu-Al/PS-based paper electrode for detecting diverse analytes in complex matrices.
Zhang, Zhiming; Zhu, Lixuan; Zhang, Yan; Zong, Yanan; Li, Yun; Zheng, Yajun; Meng, Mei; Zhang, Zhiping.
Afiliação
  • Zhang Z; School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China. zhipingzhang@xsyu.edu.cn.
  • Zhu L; School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China. zhipingzhang@xsyu.edu.cn.
  • Zhang Y; School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China. zhipingzhang@xsyu.edu.cn.
  • Zong Y; School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China. zhipingzhang@xsyu.edu.cn.
  • Li Y; Xianyang Product Quality Supervision and Inspection Institute, Xianyang 712000, China.
  • Zheng Y; School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China. zhipingzhang@xsyu.edu.cn.
  • Meng M; School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China. zhipingzhang@xsyu.edu.cn.
  • Zhang Z; School of Chemistry and Chemical Engineering, Xi'an Shiyou University, Xi'an 710065, China. zhipingzhang@xsyu.edu.cn.
Anal Methods ; 16(24): 3949-3956, 2024 Jun 20.
Article em En | MEDLINE | ID: mdl-38842287
ABSTRACT
Electrochemical sensors play a crucial role in the detection of different analytes in complex matrices, and their performance is highly dependent on the electrode capacity. However, most of the available electrodes can only be used for single-component detection, so it is urgent to develop electrodes with high sensitivity and selectivity for different components. Herein, we report an amphiprotic amino-bonded carbon nanotube-Ag/Cu/Al nanoparticle/polystyrene-coated paper electrode (CNT-Ag-Cu-Al/PS electrode), which can be used for the measurement of glucose (Glc), oxytetracycline (OTC), and hydroquinone (HQ), respectively. The results showed that the analytical sensitivity and selectivity of the CNT-Ag-Cu-Al/PS electrode were comparable to those of single metal-coated paper substrate. The developed electrode also exhibited excellent linear responses for Glc, OTC, and HQ in the ranges of 1.0-1000.0 µM, 1.0 × 10-2 to 10.0 µM, and 5.0 × 10-3 to 50.0 µM, and the limits of detection (LODs) were 0.2055 µM (Glc), 0.0074 µM (OTC), and 0.0048 µM (HQ). Owing to the characteristics of good selectivity, anti-interference, stability, and reproducibility, the CNT-Ag-Cu-Al/PS paper electrode has been successfully applied to the detection of these analytes in complex human body fluids, food, and environmental waters. The paper electrode is promising for the detection of target compounds in complex matrices.

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article