Your browser doesn't support javascript.
loading
Fetal dose assessment in a pregnant patient with brain tumor: A comparative study of proton PBS and 3DCRT/VMAT radiation therapy techniques.
Rahimi, Robabeh; Taylor, Michael; Li, Xing; Chen, Kuan Ling; MacLennan, Grayden; Murdoch, Erin; Chang, Lienard; Parniani, Ashkan; Wang, Peng; Chawla, Ashish; Fan, Jiajin; Kim, Daniel.
Afiliação
  • Rahimi R; Radiation Oncology Department, Inova Health System, Fairfax, Virginia, USA.
  • Taylor M; Radiation Oncology Department, Inova Health System, Fairfax, Virginia, USA.
  • Li X; Radiation Oncology Department, Inova Health System, Fairfax, Virginia, USA.
  • Chen KL; Radiation Oncology Department, Inova Health System, Fairfax, Virginia, USA.
  • MacLennan G; Radiation Oncology Department, Inova Health System, Fairfax, Virginia, USA.
  • Murdoch E; Radiation Oncology Department, Inova Health System, Fairfax, Virginia, USA.
  • Chang L; Radiation Oncology Department, Inova Health System, Fairfax, Virginia, USA.
  • Parniani A; Radiation Oncology Department, Inova Health System, Fairfax, Virginia, USA.
  • Wang P; Radiation Oncology Department, Inova Health System, Fairfax, Virginia, USA.
  • Chawla A; Radiation Oncology Department, Inova Health System, Fairfax, Virginia, USA.
  • Fan J; Radiation Oncology Department, Inova Health System, Fairfax, Virginia, USA.
  • Kim D; Radiation Oncology Department, Inova Health System, Fairfax, Virginia, USA.
J Appl Clin Med Phys ; : e14394, 2024 Jun 17.
Article em En | MEDLINE | ID: mdl-38887816
ABSTRACT

PURPOSE:

The treatment of brain tumors in pregnant patients poses challenges, as the out-of-field dose exposure to the fetus can potentially be harmful. A pregnant patient with prior radiation treatment was presented with a brain tumor at our clinic. This work reports on our pre-treatment study that compared fetal dose exposure between intensity-modulated proton therapy (IMPT) using pencil beam scanning (PBS) and conventional photon 3D conformal radiation therapy (3DCRT) and volumetric-modulated arc therapy (VMAT), and the subsequent pregnant patient's radiation treatment. MATERIALS AND

METHODS:

Pre-treatment measurements of clinical plans, 3DCRT, VMAT, and IMPT, were conducted on a phantom. Measurements were performed using a device capable of neutron detections, closely following AAPM guidelines, TG158. For photon measurements, fetus shielding was utilized. On patient treatment days, which was determined to be proton treatment, shielding was used only during daily imaging for patient setup. Additionally, an in vivo measurement was conducted on the patient.

RESULTS:

Measurements showed that IMPT delivered the lowest fetal dose, considering both photon and neutron out-of-field doses to the fetus, even when shielding was implemented for photon measurements. Additionally, the proton plans demonstrated superior treatment for the mother, a reirradiation case.

CONCLUSION:

The patient was treated with proton therapy, and the baby was subsequently delivered at full term with no complications. This case study supports previous clinical findings and advocates for the expanded use of proton therapy in this patient population.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article