Your browser doesn't support javascript.
loading
Determination of nine bisphenol analogues in human urine by high-throughput solid-phase extraction and ultra-high performance liquid chromatography-tandem mass spectrometry analysis.
Jin, Weiyi; Yang, Siyu; Yin, Longlong; Jia, Yeqing; Li, Xinghua; An, Kang; Li, Jianping; Zhang, Yi.
Afiliação
  • Jin W; Institute of Health Inspection and Testing, Tianjin Centers for Disease Control and Prevention, 6 Huayue Road, Hedong District, Tianjin 300011, China.
  • Yang S; Institute of Health Inspection and Testing, Tianjin Centers for Disease Control and Prevention, 6 Huayue Road, Hedong District, Tianjin 300011, China.
  • Yin L; Shandong Center for Disease Control and Prevention, Jinan, China.
  • Jia Y; Institute of Health Inspection and Testing, Tianjin Centers for Disease Control and Prevention, 6 Huayue Road, Hedong District, Tianjin 300011, China.
  • Li X; Institute of Health Inspection and Testing, Tianjin Centers for Disease Control and Prevention, 6 Huayue Road, Hedong District, Tianjin 300011, China.
  • An K; School of Public Health and Health Administration, Shandong First Medical University & Shandong Academy of Medical Sciences, 6699 Qingdao Road, Jinan City, Shandong Province 250021, China. Electronic address: healthtsmc@163.com.
  • Li J; Institute of Health Inspection and Testing, Tianjin Centers for Disease Control and Prevention, 6 Huayue Road, Hedong District, Tianjin 300011, China. Electronic address: LJP100@163.com.
  • Zhang Y; Institute of Health Inspection and Testing, Tianjin Centers for Disease Control and Prevention, 6 Huayue Road, Hedong District, Tianjin 300011, China. Electronic address: zhyi1012@163.com.
J Chromatogr A ; 1730: 465096, 2024 Aug 16.
Article em En | MEDLINE | ID: mdl-38889585
ABSTRACT
Bisphenol analogues (BPs) are a class of typical environmental endocrine-disrupting chemicals (EDCs). This study aimed to establish a highly sensitive and high-throughput method utilizing 96-well solid-phase extraction (96-well SPE) in conjunction with ultra-high performance liquid chromatography-tandem mass spectrometry (UHPLC-MS/MS) employing multiple reaction monitoring (MRM), information-dependent acquisition (IDA), and enhanced product ion (EPI) scan modes for the identification and quantitative analysis of nine BPs in human urine. Urine samples were initially thawed to room temperature, followed by digestion using ß-glucuronidase in an ammonium acetate buffer solution at 37 °C overnight. Subsequently, they were purified using 96-well SPE and finally analyzed by UHPLC-MS/MS. The limits of detection (LOD) for the nine BPs ranged from 0.05 µg∙kg-1 to 0.3 µg kg-1. Average recoveries fell within the range of 92.8 % to 111.7 %. Moreover, both the intra-day and inter-day precisions were satisfactory, with relative standard deviations (RSDs) ranging from 2.2 % to 6.7 % and 3.5 % to 6.3 %, respectively. The targets in the samples exhibited a perfect match, with a purity fit value exceeding 70 % from the self-built library. The analytical method developed in this study demonstrates high accuracy and sensitivity. In addition, the MRM-IDA-EPI mode can effectively identifies the target BPs and prevents false positive detection of analytes in the urine.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fenóis / Compostos Benzidrílicos / Espectrometria de Massas em Tandem / Extração em Fase Sólida / Limite de Detecção Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fenóis / Compostos Benzidrílicos / Espectrometria de Massas em Tandem / Extração em Fase Sólida / Limite de Detecção Idioma: En Ano de publicação: 2024 Tipo de documento: Article