Your browser doesn't support javascript.
loading
Three-Dimensional Anthropometric Facial Analysis and Fitting Discrepancies Between Stereophotogrammetry and CT.
Han, Wenqing; Yan, Yingjie; Nemani, Sriya; Sun, Mengzhe; Kim, Byeong Seop; Zhang, Yan; Zhu, Ming; Chai, Gang.
Afiliação
  • Han W; From the Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
  • Yan Y; From the Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
  • Nemani S; Department of Plastic and Reconstructive Surgery, Vanderbilt University Medical Center, Nashville, TN.
  • Sun M; From the Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
  • Kim BS; From the Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
  • Zhang Y; From the Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
  • Zhu M; Department of Plastic Surgery, Zhongshan Hospital Affiliated to Fudan University, Shanghai, China.
  • Chai G; From the Department of Plastic and Reconstructive Surgery, Shanghai Ninth People's Hospital Affiliated to Shanghai Jiaotong University School of Medicine, Shanghai, China.
Ann Plast Surg ; 93(2S Suppl 1): S82-S85, 2024 Aug 01.
Article em En | MEDLINE | ID: mdl-38896864
ABSTRACT

BACKGROUND:

The reliability and repeatability of stereophotogrammetry and CT in 3-dimensional anthropometric facial analysis were investigated in this study, which also explored the clinical application of supine CT.

METHOD:

In this study, 3D CT and 3dMD stereophotogrammetry were used on 20 healthy volunteers. The fitting distance between stereophotogrammetry and CT scans at landmark points was measured, along with facial feature measurements (Al-Al) face width (Go-Go, Zy-Zy, Ex-Ex), and hemi-face height (Sn-Gn). The intraclass correlation coefficient (ICC) was employed to assess interrater agreement and to verify the reliability of the measurement methods. Paired t -analysis was utilized for analyzing intramethod displacement.

RESULTS:

The alare, nasion, and pronasale points were found to be minimally influenced by different positions and are more recommended as landmark points for registration. CT demonstrated good interrater reliability on all indicators. In stereophotogrammetry, measurements for Go-Go and Zy-Zy displayed an interclass correlation coefficient (ICC) of less than 0.75. Significant differences between the 2 methods were observed for En-En, Ex-Ex, and Go-Go ( P < 0.05). Specifically, CT analysis for Go-Go showed a measurement 2.34 mm larger than that obtained with the 3dMD method.

CONCLUSION:

Both CT and stereophotogrammetry were found to be reliable methods for evaluating facial soft tissue. It is speculated that Go-Go measurement is primarily influenced by factors such as different positions, facial expressions, and gravity. These variables should be carefully considered during the evaluation of the mandibular angle region.
Assuntos

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fotogrametria / Tomografia Computadorizada por Raios X / Imageamento Tridimensional / Face Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Fotogrametria / Tomografia Computadorizada por Raios X / Imageamento Tridimensional / Face Idioma: En Ano de publicação: 2024 Tipo de documento: Article