Your browser doesn't support javascript.
loading
A Label-Efficient Framework for Automated Sinonasal CT Segmentation in Image-Guided Surgery.
Sahu, Manish; Xiao, Yuliang; Porras, Jose L; Amanian, Ameen; Jain, Aseem; Thamboo, Andrew; Taylor, Russell H; Creighton, Francis X; Ishii, Masaru.
Afiliação
  • Sahu M; Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland, USA.
  • Xiao Y; Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland, USA.
  • Porras JL; Department of Neurosurgery, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
  • Amanian A; Division of Otolaryngology, Department of Surgery, University of British Columbia, Vancouver, British Columbia, Canada.
  • Jain A; Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland, USA.
  • Thamboo A; Division of Otolaryngology, Department of Surgery, University of British Columbia, Vancouver, British Columbia, Canada.
  • Taylor RH; Laboratory for Computational Sensing and Robotics, Johns Hopkins University, Baltimore, Maryland, USA.
  • Creighton FX; Department of Otolaryngology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
  • Ishii M; Department of Otolaryngology, Johns Hopkins University School of Medicine, Baltimore, Maryland, USA.
Article em En | MEDLINE | ID: mdl-38922721
ABSTRACT

OBJECTIVE:

Segmentation, the partitioning of patient imaging into multiple, labeled segments, has several potential clinical benefits but when performed manually is tedious and resource intensive. Automated deep learning (DL)-based segmentation methods can streamline the process. The objective of this study was to evaluate a label-efficient DL pipeline that requires only a small number of annotated scans for semantic segmentation of sinonasal structures in CT scans. STUDY

DESIGN:

Retrospective cohort study.

SETTING:

Academic institution.

METHODS:

Forty CT scans were used in this study including 16 scans in which the nasal septum (NS), inferior turbinate (IT), maxillary sinus (MS), and optic nerve (ON) were manually annotated using an open-source software. A label-efficient DL framework was used to train jointly on a few manually labeled scans and the remaining unlabeled scans. Quantitative analysis was then performed to obtain the number of annotated scans needed to achieve submillimeter average surface distances (ASDs).

RESULTS:

Our findings reveal that merely four labeled scans are necessary to achieve median submillimeter ASDs for large sinonasal structures-NS (0.96 mm), IT (0.74 mm), and MS (0.43 mm), whereas eight scans are required for smaller structures-ON (0.80 mm).

CONCLUSION:

We have evaluated a label-efficient pipeline for segmentation of sinonasal structures. Empirical results demonstrate that automated DL methods can achieve submillimeter accuracy using a small number of labeled CT scans. Our pipeline has the potential to improve pre-operative planning workflows, robotic- and image-guidance navigation systems, computer-assisted diagnosis, and the construction of statistical shape models to quantify population variations. LEVEL OF EVIDENCE N/A.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article