Your browser doesn't support javascript.
loading
Assessing asymmetrical kidney function in living donors: a retrospective cohort study on CT metrics.
Sturman, Joseph; Fenton, Anthony; Hayat, Usman; Jones, Robert; Lipkin, Graham.
Afiliação
  • Sturman J; Department of Renal Medicine, University Hospitals Birmingham NHS Foundation Trust, Queen Elizabeth Hospital Birmingham, Mindelsohn Way, Edgbaston, Birmingham, B15 2GW, UK. j.d.sturman@bham.ac.uk.
  • Fenton A; Institute of Immunology and Immunotherapy, College of Medical and Dental Sciences, University of Birmingham, Edgbaston, Birmingham, B15 2TT, UK. j.d.sturman@bham.ac.uk.
  • Hayat U; Kidney Unit, Royal Stoke University Hospital, Newcastle Road, Stoke-on-Trent, ST4 6QG, UK.
  • Jones R; Department of Renal Medicine, University Hospitals Birmingham NHS Foundation Trust, Queen Elizabeth Hospital Birmingham, Mindelsohn Way, Edgbaston, Birmingham, B15 2GW, UK.
  • Lipkin G; Department of Interventional Radiology, University Hospitals Birmingham NHS Foundation Trust, Queen Elizabeth Hospital Birmingham, Mindelsohn Way, Edgbaston, Birmingham, B15 2GW, UK.
BMC Nephrol ; 25(1): 214, 2024 Jul 02.
Article em En | MEDLINE | ID: mdl-38956529
ABSTRACT

BACKGROUND:

Live donor kidney transplantation is the preferred kidney replacement therapy for eligible patients but requires thorough donor evaluation to minimise risks. Contemporary guidelines recommend split kidney function measurement in living donors only when there is a significant kidney size discrepancy, yet the evidence for this is poor, and practice varies nationally. This study evaluates the efficacy of CT-derived kidney metrics in detecting significant functional asymmetry.

METHODS:

We conducted a retrospective cohort analysis of 123 prospective living kidney donors at a regional transplant centre from June 2011 to October 2014, utilising CT to determine kidney and cortical volumes and lengths. Asymmetric kidney function (AKF), defined by > 10% function difference on DMSA scans, was correlated with CT measurements to calculate the diagnostic accuracy of current guidelines.

RESULTS:

Among the prospective donors, the median age was 42 years, and 59.3% were female. The median split kidney function difference was 4%, with 25 individuals exhibiting > 10% AKF. Kidney length discrepancy proved to be a poor indicator of AKF (sensitivity 28%, specificity 84%). While negative predictive values for cortical and kidney volumes were high (96% and 93%, respectively), sensitivity was low, and specificity and positive predictive value did not meet satisfactory thresholds.

CONCLUSIONS:

CT-derived metrics of kidney length, cortical, and total volume show limited sensitivity and specificity in identifying significant AKF. These findings provide evidence to support revised guideline development in the assessment of living kidney donors.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Transplante de Rim / Doadores Vivos / Rim Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Tomografia Computadorizada por Raios X / Transplante de Rim / Doadores Vivos / Rim Idioma: En Ano de publicação: 2024 Tipo de documento: Article