Your browser doesn't support javascript.
loading
Development of cross-linked glucose oxidase integrated Cu-nanoflower electrode for reusable and stable glucose sensing.
Kim, Keon Woo; Kim, Dain; Kim, Byoung Chan; Hwang, Ee Taek.
Afiliação
  • Kim KW; Department of Food Biotechnology, Dong-A University, Busan 49315, Republic of Korea.
  • Kim D; Department of Food Biotechnology, Dong-A University, Busan 49315, Republic of Korea.
  • Kim BC; Center for Sustainable Environment Research, Korea Institute of Science and Technology (KIST), Seoul 02792, Republic of Korea; Division of Energy and Environment Technology, KIST School, University of Science and Technology (UST), Seoul 02792, Republic of Korea.
  • Hwang ET; Department of Food Biotechnology, Dong-A University, Busan 49315, Republic of Korea. Electronic address: ethwang@dau.ac.kr.
Int J Biol Macromol ; 275(Pt 2): 133605, 2024 Aug.
Article em En | MEDLINE | ID: mdl-38971285
ABSTRACT
The demand for glucose-sensing devices has increased along with the increasing diabetic population. Here, we aimed to construct a system with a glucose oxidase (GOx)-integrated Cu-nanoflower (Cu-NF) as the underlying electrode. This novel system was successfully developed by creating a cross-linked GOx within a Cu-NF matrix, forming a c-GOx@Cu-NF-coated film on a carbon screen-printed electrode (CSPE). A comparison of the stabilities of the cross-linking methods demonstrated enhanced durability, with an activity level of >88 % maintained after approximately 35 days of storage in room temperature buffer. Regarding the ability of the c-GOx@Cu-NF modified CSPE to detect glucose via electrochemical methods, the redox potential gap (ΔE) and peak current increased in the presence of GOx. In comparison to that of glucose, the sensitivity of c-GOx@Cu-NF was approximately 8 times greater than that of GOx@Cu-NF, with a detection limit of 0.649 µM and a linear range of 5-500 µM. It sustained an average relative activity of 80 % over 20 days. After 10 cycles of repeated use, the activity remained above 75 %. In terms of evaluating the electrode's specificity for glucose, the detection rate for individual similar substances was approximately 1 %. The introduction of a crosslinking strategy to Cu-NF, leading to enhanced mechanical stability and conductivity, improved the detection capability. Furthermore, this approach led to increased long-term storage stability and reusability, allowing for specific glucose detection. To our knowledge, this report represents the first demonstration of a c-GOx@Cu-NF system for integrating electrochemical biosensing devices into digital healthcare pathways, offering enhanced sensing accuracy and mechanical stability.
Assuntos
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Cobre / Eletrodos / Glucose / Glucose Oxidase Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Assunto principal: Técnicas Biossensoriais / Cobre / Eletrodos / Glucose / Glucose Oxidase Idioma: En Ano de publicação: 2024 Tipo de documento: Article