Your browser doesn't support javascript.
loading
Fabrication of a salivary amylase electrochemical sensor based on surface confined MWCNTs/ß-cyclodextrin/starch architect for dental caries in clinical samples.
Asghar, Hira; Tariq, Aqsa; Rasool, Ghulam; Hayat, Akhtar.
Afiliação
  • Asghar H; Institute of Molecular Biology and Biotechnology, The University of Lahore, 1-km Defence Road, near Bhuptian Chowk, Lahore 54000, Pakistan; Interdisciplinary Research Center in Biomedical Materials (IRCBM), COMSATS University, Islamabad, Lahore Campus, Lahore 54000, Pakistan; Azra Naheed Dental Coll
  • Tariq A; Interdisciplinary Research Center in Biomedical Materials (IRCBM), COMSATS University, Islamabad, Lahore Campus, Lahore 54000, Pakistan.
  • Rasool G; Institute of Molecular Biology and Biotechnology, The University of Lahore, 1-km Defence Road, near Bhuptian Chowk, Lahore 54000, Pakistan. Electronic address: ghulam.rasool@imbb.uol.edu.pk.
  • Hayat A; Interdisciplinary Research Center in Biomedical Materials (IRCBM), COMSATS University, Islamabad, Lahore Campus, Lahore 54000, Pakistan. Electronic address: akhtarhayat@cuilahore.edu.pk.
Bioelectrochemistry ; 160: 108774, 2024 Jul 06.
Article em En | MEDLINE | ID: mdl-38981325
ABSTRACT
Salivary α-amylase (α-ALS) has drawn attention as a possible bioindicator for dental caries. Herein, combining the synergistic properties of multi-walled carbon nanotubes (MWCNTs), ß-cyclodextrin (ß-CD) and starch, an electrochemical sensor is constructed employing ferrocene (FCN) as an electrochemical indicator to oversee the progression of the enzymatic catalysis of α-ALS. The method involves a two-step chemical reaction sequence on a screen-printed carbon electrode (SPCE). X-ray diffraction (XRD), Fourier transform infrared (FTIR) spectroscopy, Field emission scanning electron microscope (FE-SEM), and Dynamic light scattering (DLS) were used to characterize the synthesized material, while Static water Contact angle measurements, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) were performed to monitor each step of sensor fabrication. The electrochemical sensor permitted to detect α-ALS within the linear range of 0.5-280 U mL-1, revealing detection (LOD), and quantification (LOQ) values of 0.041 U mL-1, and 0.159 U mL-1, respectively. Remarkably, the sensor demonstrated exceptional specificity and selectivity, effectively discriminating against other interfering substances in saliva. Validation of the method involved analyzing α-ALS levels in artificial saliva with an accuracy range of 97 % to 103 %, as well as in real clinical saliva samples across various age groups.
Palavras-chave

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article

Texto completo: 1 Base de dados: MEDLINE Idioma: En Ano de publicação: 2024 Tipo de documento: Article